S60Fire criteria · duration

60-minute fire door

A 60-minute fire door is a door that resists fire for at least 60 minutes; depending on what the project requires, its class is EI60 (integrity and insulation) or EW60 (integrity and limited radiation). In a new building, the door of an escape stair serving fewer than 4 storeys, a fire compartment line and a smoke barrier in a hotel corridor need at least 60 minutes. If the stair serves a basement or more than 4 storeys, 90 minutes is required.

EI60 fire door Turkey – glass partition and double leaf in an office corridor
60-minute door on a compartment line
Class letters
E integrity · I insulation · W radiation
Stair, fewer than 4 storeys
At least 60 min
Compartment line
At least 60 min
Hotel smoke barrier
At least 60 min
Polflam EI60 glass
25 mm

01 Enough?

Is 60 minutes enough for your door?

Choose the door's location; the scale compares the required duration with a 60-minute and a 90-minute door.

1Location

Does it go down to a basement?

60minutesminimum · this location

The escape stair serves 3 storeys: fewer than 4. The door needs at least 60 minutes; 60 minutes is enough.

  • 60 minutes is enoughGlass 25 mm
  • Smoke-tightRequired by the article
  • Self-closingWith a closer
  • Report for its own typeSingle or double

Source: BYKHY 4(1)(tt), 24(7), 25(2), 47(3), 50(6)(a), 157(1)

0306090120minutesrequired by location60-min door90-min doorMINUTE SCALE · diagram–
Required here60 minutes90 minutes

02 What the door needs

What to look for in a 60-minute door

First the floor door of an escape stair, then the smoke barrier in a hotel corridor; tap to hold the view.

EI60 fire door Turkey – stair landing in a three-storey office

1 / 2 · Floor door of an escape stairCamera on the stair; fire in the floor corridor.

Rating≥ 60 minGlass25 mm

  1. DurationIf the stair serves fewer than 4 storeys, the door resists fire for at least 60 minutes.
  2. CloserThe door is fitted with a self-closing device; the article also requires it to be smoke-tight.
  3. GlassA 60-minute glazed door uses Polflam EI60 glass: 25 mm.

Source: BYKHY 47(3); Polflam catalogue

03 Building section

Where do 60 and 90 minutes part ways in a building?

A building with a ground floor and two upper floors: escape stair, compartment wall and fire wall towards the neighbouring building. Choose a rule; its place in the section shows in orange.

What does EI60 tell you?

In the regulation's symbol table, E is integrity and I is insulation. A door marked EI60 maintains its integrity for 60 minutes in a fire and insulates its unexposed face. In EW60, W takes the place of I: the door maintains its integrity and, instead of insulation, limits the heat passing by radiation.

ExampleFirst-floor door of the stair in the section: EI 60.

Source: BYKHY Annex 3/A

basement (if any)escape staircompartment wallfire wallneighbouring buildingbuilding heightBUILDING SECTION · diagramEI 60123456
Floor and wallSelected rule

04 Four locations

Where are 60-minute fire doors used?

Four situations; choose a location and what is required of the door there is marked beside it.

05 Your project

Does your project need 60 or 90 minutes?

These four answers set the duration.

  1. 01

    How many storeys does the stair serve?

    If fewer than 4, doors are 60 minutes; if more, 90; exactly 4 storeys is settled in the project.

  2. 02

    Is there a basement?

    The doors of an escape stair going down to a basement need 90 minutes.

  3. 03

    Which line is the door on?

    60 on a compartment line; on a fire wall, half the wall's duration.

  4. 04

    In an existing building, how many metres high is it?

    In an existing building lower than 30.50 m, 60 minutes is enough for the stair door.

Send your door list and we will sort out the durations together. A floor section and the door locations are enough; our technical team will review them.

Send the project

06 Products

Which glazed doors are made with 60-minute fire resistance?

Aliplast FR65 and FR90 profiles, Polflam EI60 glass.

  1. FR65 · FR90

    Single leaf

    Stair and lobby doors, 30 and 60 minutes. Single leaf

  2. FR90

    Double leaf

    A wide door crossing a compartment line; it has a 60-minute classification. Double leaf

  3. Made by Abay

    Automatic sliding

    60-minute automatic sliding door (EI60). Automatic sliding

The glass of a 60-minute line outside the door carries the same duration. Fixed glass partition

Abay Yapı Sistemleri

Trusted for 30 years.

We make 60-minute doors and partitions with Aliplast profiles and 25 mm Polflam glass, to each project's dimensions in our Istanbul workshop.

154
corporate references
Aliplast
authorised manufacturer and distributor in Turkey
Polflam
partner for fire-resistant glass
Istanbul
head office and production, Istanbul
EI60 fire door project Turkey – double leaf held open in a lift lobbyEI60 fire door project Turkey – double leaf with panic bars, side and top lightsEI60 fire door project Turkey – door and glass partition in a lift lobbyEI60 fire door project Turkey – stair front at a restaurant entrance
Lift lobby · Double leaf · top light
30yearsof trusted manufacturing and installation
  1. 01Project and useBuilding type, required rating, door location
  2. 02Size and openingOverall size, clear width, opening direction
  3. 03System and hardwareProfile, glass, lock, closer
  4. 04Quote and productionScope agreed, delivered with the document set

Projects

Stair and corridor doors from our reference projects.

Doors we have installed at stair entrances and on lines that cut across corridors. Tap a photo; browse with the arrows.

07 Document set

Which document states the duration of a 60-minute door?

The door's class is in the report issued for its own type; the thickness and class of the glass are in the Polflam declaration.

Four checks at handover

  1. Duration. The report must state 60 minutes or a longer duration; the class is EI60 or EW60, as the project requires.
  2. Type. The report for a double-leaf door must have been issued for a double leaf.
  3. Smoke. At stair and smoke barrier doors the article also requires smoke-tightness.
  4. Glass. The project uses the glass tested in the report.
  • ClassificationFR90 double leaf · 60 minutesFIRES-CR-178-17-AUPEDocument centre
  • ClassificationFR65 door and partitionEI 30 · EI 60Document centre
  • DeclarationPolflam EI60 glass25 mmDocument centre
  • AuthorisationAliplast manufacturing authorisationAbay Yapı's manufacturing authorisationDocument centre

Source: Aliplast and Polflam documents

Request the document set for your 60-minute doors. The set is prepared for the door type and size.

Document centre

08 FAQ

About 60-minute fire doors

Whether a door is 60 or 90 minutes is settled in the project according to the storeys the stair serves and the line the door is on. Send your section and we will sort out the durations together.

0216 428 38 20Send a question

What does EI60 mean?

EI60 shows that the door maintains its integrity (E) and insulation (I) for 60 minutes in a fire. The meaning of the letters is given in the regulation's symbol table; the number is minutes. In EW60, W takes the place of I: the door maintains its integrity and, instead of insulation, limits the heat passing by radiation.

Source: BYKHY Annex 3/A

Where are 60-minute fire doors mandatory?

In a new building, at least 60 minutes is required at the door of an escape stair serving fewer than 4 storeys, on a fire compartment line, at the door of a smoke barrier in a hotel corridor and at a door in a 120-minute fire wall. Doors where 30 minutes is enough are on the 30-minute fire door page.

Source: BYKHY 4(1)(tt), 25(2), 47(3), 50(6)(a)

What is the difference between a 60-minute and a 90-minute door?

The difference is 30 minutes. If the escape stair serves a basement or more than 4 storeys, the door must resist at least 90 minutes; 60 minutes is not enough and a 90-minute fire door is needed. In a glazed door, Polflam glass is 25 mm in EI60 and 32 mm in EI90.

Source: BYKHY 47(3); Polflam catalogue

How thick is EI60 fire glass?

Polflam EI60 glass is 25 mm thick. The 60 minutes of the door or partition, however, are shown by the report in which the glass was tested together with the profile.

Source: Polflam catalogue

How many minutes should an apartment block stair door resist?

On an apartment block stair that does not go down to a basement and serves fewer than 4 storeys, 60 minutes is enough for the door; if there is a basement or more than 4 storeys, the duration rises to 90 minutes. The article also requires this door to be smoke-tight and self-closing.

Source: BYKHY 47(3)

How many minutes should a stair door in an existing building resist?

In existing buildings, if the total building height is less than 30.50 m the stair door resists fire for at least 60 minutes, and if it is 30.50 m or more, at least 90 minutes; the door is smoke-tight and at least 70 cm wide and 190 cm high.

Source: BYKHY 157(1)

How many minutes should a door in a fire wall resist?

At least half the wall's resistance: at least 60 minutes in a 120-minute fire wall. The regulation also requires this door to close by itself and not to let smoke through.