B2Documents and compliance · guide
Fire door certificate How do you check it?
A fire door certificate is checked with five matches: the report is one in which the profile and glass were tested together, the product type in the report is the same as in the project, the leaf in the project is not larger than the tested specimen, the etched stamp in the glass corner shows the glass in the report, and the manufacturer holds an authorisation from the system owner. The report is issued by an approval body.
Etched stamp
- Issued by
- Approval body
- Profile and glass
- Tested in the same specimen
- Leaf in the project
- Not larger than the specimen
- Mark on the glass
- Etched stamp in the corner
- Manufacturer in Turkey
- With an authorisation
01 Five questions
Does your certificate cover your door?
Put the report in the quote next to the door; answer each question.
1Were the profile and glass tested together?
2Is the type in the report the same as in the project?
3Is the leaf within the specimen size?
4Is the glass on the stamp the glass in the report?
5Does the manufacturer have an authorisation?
5/5matchesreport and door
All five checks match: the report covers this door. On delivery, the label, invoice and authorisation certificate refer to the same door.
Source: Abay check note; BYKHY 4(1)(ğğ), 6(1)
02 What the door needs
How is a certificate verified on an installed door?
First the glass corner, then the frame and hardware; tap to fix the view.
1 / 2 · Stamp in the glass cornerCamera on the escape side; the fire is behind the glass.
- StampA permanent mark applied to the corner of the glass; its brand and class are compared with the glass in the report.
- GlassThe pane sits inside the frame, its edges within the profile; its size does not exceed the one in the report.
- Bottom frameThe leaf and frame are the profiles of the tested system; a frame from another system invalidates the report.
Source: Abay check note; Aliplast FR90 test report (ITB, 2020)
2 / 2 · Frame, label and hardwareThe label links the door to the report, the invoice and the manufacturer.
- LabelThe plate on the frame carries the class, system, serial number and glass; it must match the manufacturer on the invoice.
- CloserThe closer model tested in the report is also used on the door.
- HingeHinges and locks are also chosen from the hardware list in the report.
Source: Aliplast FR90 test report: WALA hinge, SOBINCO lock, GEZE TS 5000 closer
03 What is in the report
Where to look in a fire test report?
The first pages of the report carry six pieces of information. Select a row; its place on the diagram turns orange.
Who issued the report?
The certificate is issued by TSE, or by an international approval body accepted by TSE, after testing the product. The body's name and accreditation are written at the start of the report.
ExampleThe report for the FR90 single leaf was issued by ITB in Poland; the body is accredited under EU number 023.
Source: BYKHY 4(1)(ğğ)
To which standard was it tested?
Where the Regulation has no sufficient provision, Turkish standards apply first, then European standards. The report states which standard the test followed.
ExampleThe report for the FR90 single leaf states EN 1634-1+A1:2018 and EN 16034:2014.
Source: BYKHY 5(2)
What size was the tested door?
The report states the type and size of the specimen placed in the furnace. According to Abay's check note, the leaf and glass pane in the project should not be larger than this size.
ExampleThe FR90 single-leaf specimen was 1,450 × 2,600 mm, and its leaf 1,340.6 × 2,535 mm.
Source: Aliplast FR90 test report (ITB, 2020); Abay check note
Which glass was in the test?
The report states the brand, thickness and size of the glass tested with the profile. The same glass is used in the project; the etched stamp in the glass corner is compared with it.

ExamplePolflam 90 glass was tested in the FR90 single leaf: 35 mm, 1,187 × 2,382 mm.
Source: Aliplast FR90 test report (ITB, 2020); Abay check note
What do the minutes and letters say?
The results section states for how many minutes integrity (E) and insulation (I) were maintained. The meaning of the letters is in the Regulation's symbol table.
ExampleIn the FR90 fire test, both specimens kept out flame and smoke for 103 minutes.
Source: BYKHY Annex 3/A; Aliplast FR90 test report
Is a test report enough on its own?
For a construction product covered by a harmonised standard, the manufacturer issues a declaration of performance. The test report is the record of the test; the product's class is set by the classification report.
ExampleThe ITB report states in its own disclaimer that it is not a document admitting the product to trade and general use.
Source: Turkish Construction Products Regulation 6(1); Aliplast FR90 test report
04 Four matches
When does a certificate not cover the door?
Four cases where the document breaks away from the door; select one and the match to look for is marked alongside.
Fire side
Escape side
- Profile and glass together A door's duration is shown by a report in which the profile and glass were tested in the same specimen. A certificate for the glass alone, or fire glass fitted later into a steel door, does not replace this report. BYKHY 4(1)(ğğ)Same specimen
- Glass brand in the test The profile–glass pair in the report is also used in the project. If the profile is Aliplast but the glass comes from a manufacturer other than the tested one, the FR90 report does not cover that partition. BYKHY 4(1)(ğğ)Same pair
- Single, double and fixed separately Single leaf, double leaf and fixed partition are each tested separately. A test made with fixed glazing does not carry over to a door, nor a single-leaf test to a double leaf. BYKHY 4(1)(ğğ)Separate report
- Manufacturer's authorisation The system owner commissions the report; if another company manufactures the door in Turkey, it obtains a manufacturing authorisation from the system owner. This certificate ensures the report is used only for the authorised manufacturer's work. BYKHY 6(1)Authorisation
05 Your quote
What to ask the supplier when getting a quote?
These four questions reveal the link from the report to the door.
- 01
Which report is in the quote?
Ask for the report number and the product type it was issued for.
- 02
Are your doors larger than in the report?
Put your leaf and glass sizes next to the specimen in the report.
- 03
Which brand is the glass?
The glass brand in the quote must be the same as the glass tested with the profile in the report.
- 04
Who manufactures the door?
The manufacturing company must hold an authorisation from the system owner who commissioned the report.
Let's read your report together. Send the report number and your door list; our technical team will compare the scope.
Send the report06 Products
How do these matches look on our doors?
Aliplast profiles, Polflam glass, authorised manufacturing in Istanbul.
Document set
Documents for fire brigade and occupancy
The set we prepare by door type and duration. Fire door documents
System
Aliplast FR90
Test and classification results for single and double leaf. FR90
Glass
Polflam fire glass
Thickness, class and declarations of performance. Fire-resistant glass
The criteria pages show the duration required where the door is located. Fire criteria
Abay Yapı Sistemleri
Trusted for 30 years.
In our Istanbul workshop we assemble the Aliplast profiles and Polflam glass tested together in the reports to the project's sizes.
- 154
- corporate references
- Aliplast
- authorised manufacturer and distributor in Turkey
- Polflam
- partner for fire-resistant glass
- Istanbul
- head office and production, Istanbul



- 01Project and useBuilding type, required rating, door location
- 02Size and openingOverall size, clear width, opening direction
- 03System and hardwareProfile, glass, lock, closer
- 04Quote and productionScope agreed, delivered with the document set
Projects
Doors from our reference projects, made with the tested system.
Top row: our single-leaf doors and doors with side lights; bottom row: double-leaf doors and partitions. Tap a photo; browse with the arrows.
07 Our documents
Documents you can request for the check
Each of the five matches is compared against one of these documents.
Which question, which document
- Tested together. The specimen section of the test or classification report.
- Type and size. The report's product description and specimen sizes.
- Glass. The glass line of the report and the Polflam declaration.
- Manufacturer. Aliplast manufacturing authorisation and invoice.
- Test reportFR90 single leaf · ITB 2020Specimen 1,450 × 2,600 mm · Polflam 90Request it
- Test reportFR90 double-leaf glazed doorITB 2020 · specimen 2,770 × 2,600 mm · 98 minutesRequest it
- ClassificationFR90 double leaf · 60 minutesFIRES-CR-178-17-AUPERequest it
- DeclarationPolflam EI30–EI120 glassFor comparison with the glass stampRequest it
- AuthorisationAliplast manufacturing authorisationAbay Yapı's manufacturing authorisationRequest it
Source: Aliplast and Polflam documents
Request the documents for comparison. Reports are sent with company and project details.
Request the documents08 FAQ
About the certificate check
If you are not sure whether a report covers your door, send the report number; we will compare the specimen, glass and size together.
How do you check a fire door certificate?
Five matches are checked: the report is one in which the profile and glass were tested together, the product type in the report is the same as in the project, the leaf in the project is not larger than the specimen, the etched stamp on the glass shows the glass in the report, and the manufacturer holds an authorisation from the system owner. The report must also be issued by an approval body.
Source: BYKHY 4(1)(ğğ); Abay check note
What is an etched stamp and where is it?
It is a permanent mark applied to the corner of fire glass; it is not a label that can be removed and refitted. It shows the brand and class of the glass and is compared with the glass in the door's report.

Source: Abay check note
How do you tell fire glass from ordinary glass?
Once installed, it is hard to tell from the outside. The first place to look is the etched stamp in the glass corner and the glass label; the brand and class on the stamp must match the glass in the door's report.
Source: Abay check note
Does fitting fire glass into a steel door make it a fire door?
A door's duration is shown by a report in which the leaf was tested together with its glass and frame. For fire glass fitted later into a steel door, the glass certificate does not show the duration; the leaf needs its own test.
Source: BYKHY 4(1)(ğğ)
Can a door larger than the tested one be made?
The report states the size of the tested specimen; according to Abay's check note, the leaf and glass pane in the project should not exceed this size. If a larger size is needed, the scope of the report is checked with the system owner.
Source: Abay check note
Is a test report the document that admits the product to the market?
No. The ITB report for the FR90 single leaf says so in its own disclaimer. For a product covered by a harmonised standard, the manufacturer issues a declaration of performance; the class is set by the classification report.
Source: Turkish Construction Products Regulation 6(1); Aliplast FR90 test report
Can the profile and glass come from different manufacturers?
Whichever profile was tested with whichever glass in the report, that pair is used in the project. In the FR90 reports the Aliplast profile was tested with Polflam glass; if glass other than the tested one is fitted, the report does not cover that door.
Source: Aliplast FR90 documents; Abay check note
→ Quote
Let's compare the report together.
Write your report number and door list: our technical team will compare the specimen, glass and size with your doors and get back to you.
- Phone
- +90 216 428 38 20
- abay@abayyapi.com
- Production