B2Documents and compliance · guide

Fire door certificate How do you check it?

A fire door certificate is checked with five matches: the report is one in which the profile and glass were tested together, the product type in the report is the same as in the project, the leaf in the project is not larger than the tested specimen, the etched stamp in the glass corner shows the glass in the report, and the manufacturer holds an authorisation from the system owner. The report is issued by an approval body.

Fire door certification Turkey – CE Polflam EI 90 stamp on the glass
Etched stamp in the glass corner
Issued by
Approval body
Profile and glass
Tested in the same specimen
Leaf in the project
Not larger than the specimen
Mark on the glass
Etched stamp in the corner
Manufacturer in Turkey
With an authorisation

01 Five questions

Does your certificate cover your door?

Put the report in the quote next to the door; answer each question.

1Were the profile and glass tested together?

2Is the type in the report the same as in the project?

3Is the leaf within the specimen size?

4Is the glass on the stamp the glass in the report?

5Does the manufacturer have an authorisation?

5/5matchesreport and door

All five checks match: the report covers this door. On delivery, the label, invoice and authorisation certificate refer to the same door.

Source: Abay check note; BYKHY 4(1)(ğğ), 6(1)

leaf widthheightELEVATION · diagramprofile + glass1product type2size3glass stamp4frame label5
MatchesDoes not match

02 What the door needs

How is a certificate verified on an installed door?

First the glass corner, then the frame and hardware; tap to fix the view.

Fire door certificate Turkey – etched stamp on the glass

1 / 2 · Stamp in the glass cornerCamera on the escape side; the fire is behind the glass.

StampIn the cornerGlass= report

  1. StampA permanent mark applied to the corner of the glass; its brand and class are compared with the glass in the report.
  2. GlassThe pane sits inside the frame, its edges within the profile; its size does not exceed the one in the report.
  3. Bottom frameThe leaf and frame are the profiles of the tested system; a frame from another system invalidates the report.

Source: Abay check note; Aliplast FR90 test report (ITB, 2020)

03 What is in the report

Where to look in a fire test report?

The first pages of the report carry six pieces of information. Select a row; its place on the diagram turns orange.

Who issued the report?

The certificate is issued by TSE, or by an international approval body accepted by TSE, after testing the product. The body's name and accreditation are written at the start of the report.

ExampleThe report for the FR90 single leaf was issued by ITB in Poland; the body is accredited under EU number 023.

Source: BYKHY 4(1)(ğğ)

laboratorystandardspecimenglassresultdocument typeEIminutesspecimenDOOR IN THE REPORTTEST REPORT · diagram123456
Selected rowFire glass

04 Four matches

When does a certificate not cover the door?

Four cases where the document breaks away from the door; select one and the match to look for is marked alongside.

05 Your quote

What to ask the supplier when getting a quote?

These four questions reveal the link from the report to the door.

  1. 01

    Which report is in the quote?

    Ask for the report number and the product type it was issued for.

  2. 02

    Are your doors larger than in the report?

    Put your leaf and glass sizes next to the specimen in the report.

  3. 03

    Which brand is the glass?

    The glass brand in the quote must be the same as the glass tested with the profile in the report.

  4. 04

    Who manufactures the door?

    The manufacturing company must hold an authorisation from the system owner who commissioned the report.

Let's read your report together. Send the report number and your door list; our technical team will compare the scope.

Send the report

06 Products

How do these matches look on our doors?

Aliplast profiles, Polflam glass, authorised manufacturing in Istanbul.

  1. Document set

    Documents for fire brigade and occupancy

    The set we prepare by door type and duration. Fire door documents

  2. System

    Aliplast FR90

    Test and classification results for single and double leaf. FR90

  3. Glass

    Polflam fire glass

    Thickness, class and declarations of performance. Fire-resistant glass

The criteria pages show the duration required where the door is located. Fire criteria

Abay Yapı Sistemleri

Trusted for 30 years.

In our Istanbul workshop we assemble the Aliplast profiles and Polflam glass tested together in the reports to the project's sizes.

154
corporate references
Aliplast
authorised manufacturer and distributor in Turkey
Polflam
partner for fire-resistant glass
Istanbul
head office and production, Istanbul
Fire door certification project Turkey – double leaf held open in a lift lobbyFire door certification project Turkey – door and glass partition in a lift lobbyFire door certification project Turkey – double leaf with panic bars, side and top lights
Lift lobby · Double leaf · top light
  1. 01Project and useBuilding type, required rating, door location
  2. 02Size and openingOverall size, clear width, opening direction
  3. 03System and hardwareProfile, glass, lock, closer
  4. 04Quote and productionScope agreed, delivered with the document set

Projects

Doors from our reference projects, made with the tested system.

Top row: our single-leaf doors and doors with side lights; bottom row: double-leaf doors and partitions. Tap a photo; browse with the arrows.

07 Our documents

Documents you can request for the check

Each of the five matches is compared against one of these documents.

Which question, which document

  1. Tested together. The specimen section of the test or classification report.
  2. Type and size. The report's product description and specimen sizes.
  3. Glass. The glass line of the report and the Polflam declaration.
  4. Manufacturer. Aliplast manufacturing authorisation and invoice.
  • Test reportFR90 single leaf · ITB 2020Specimen 1,450 × 2,600 mm · Polflam 90Request it
  • Test reportFR90 double-leaf glazed doorITB 2020 · specimen 2,770 × 2,600 mm · 98 minutesRequest it
  • ClassificationFR90 double leaf · 60 minutesFIRES-CR-178-17-AUPERequest it
  • DeclarationPolflam EI30–EI120 glassFor comparison with the glass stampRequest it
  • AuthorisationAliplast manufacturing authorisationAbay Yapı's manufacturing authorisationRequest it

Source: Aliplast and Polflam documents

Request the documents for comparison. Reports are sent with company and project details.

Request the documents

08 FAQ

About the certificate check

If you are not sure whether a report covers your door, send the report number; we will compare the specimen, glass and size together.

0216 428 38 20Send a question

How do you check a fire door certificate?

Five matches are checked: the report is one in which the profile and glass were tested together, the product type in the report is the same as in the project, the leaf in the project is not larger than the specimen, the etched stamp on the glass shows the glass in the report, and the manufacturer holds an authorisation from the system owner. The report must also be issued by an approval body.

Source: BYKHY 4(1)(ğğ); Abay check note

What is an etched stamp and where is it?

It is a permanent mark applied to the corner of fire glass; it is not a label that can be removed and refitted. It shows the brand and class of the glass and is compared with the glass in the door's report.

Fire door certification check Turkey – CE Polflam EI 90 stamp in the glass corner
CE mark · POLFLAM brand · EI 90 class · 22 year · EN 12150-2 standard · NB1487 notified bodyHow to read the stamp?

Source: Abay check note

How do you tell fire glass from ordinary glass?

Once installed, it is hard to tell from the outside. The first place to look is the etched stamp in the glass corner and the glass label; the brand and class on the stamp must match the glass in the door's report.

Source: Abay check note

Does fitting fire glass into a steel door make it a fire door?

A door's duration is shown by a report in which the leaf was tested together with its glass and frame. For fire glass fitted later into a steel door, the glass certificate does not show the duration; the leaf needs its own test.

Source: BYKHY 4(1)(ğğ)

Can a door larger than the tested one be made?

The report states the size of the tested specimen; according to Abay's check note, the leaf and glass pane in the project should not exceed this size. If a larger size is needed, the scope of the report is checked with the system owner.

Source: Abay check note

Is a test report the document that admits the product to the market?

No. The ITB report for the FR90 single leaf says so in its own disclaimer. For a product covered by a harmonised standard, the manufacturer issues a declaration of performance; the class is set by the classification report.

Source: Turkish Construction Products Regulation 6(1); Aliplast FR90 test report

Can the profile and glass come from different manufacturers?

Whichever profile was tested with whichever glass in the report, that pair is used in the project. In the FR90 reports the Aliplast profile was tested with Polflam glass; if glass other than the tested one is fitted, the report does not cover that door.

Source: Aliplast FR90 documents; Abay check note

→ Quote

Let's compare the report together.

Write your report number and door list: our technical team will compare the specimen, glass and size with your doors and get back to you.

Call · 0216 428 38 20Email

Production
Istanbul

Quote form* required field

CallRequest a quote