P6Products · price
Fire door prices: What does the price of a glazed door depend on?
A glazed fire door has no single list price; its price is set by the fire rating, profile system, size, leaf and fixed glass layout, glass and hardware together. For this reason the quote is prepared per project once the door's location and size are clear. The six factors below also show what you need to send.
- Ratings
- EI30 – EI120
- Systems
- Aliplast FR65 · FR90
- Leaf
- Single · double · with side light
- Quote
- Per project
01 Six factors
Which factors determine the price of a glazed fire door?
Under each factor there is a page that explains it in detail.
01
Fire rating
EI30, EI60, EI90 or EI120: the class determines the glass and the system. The door's location tells you which class is required. Fire resistance ratings
02
Profile system
FR65: EI30 and EI60 doors for interiors; FR90: doors up to EI90 and partitions up to EI120, interior and exterior. FR90 FR65
03
Sizes
Overall size, clear opening and glass module. In FR90 a single leaf is made up to 1,650 × 2,870 mm. Size limits
04
Leaf and fixed glass layout
Single-leaf, double-leaf, with one side light, with two side lights or with a top light; the automatic sliding door is a separate system. Single leaf Double leaf With side lights
05
Glass
Glass thickness changes with the rating; a frameless, glass-to-glass partition uses a separate glass family. Fire-resistant glass
06
Hardware and colour
Panic hardware, lock, door closer, automation and RAL colour are chosen together with the scope of the documents. Request a quote
02 Glass thickness
How does glass thickness change with the fire rating?
Selected Polflam glass products; values are not the same for every glass type.
| Polflam glass | Nominal thickness | Light transmission |
|---|---|---|
| EI30 | 20 mm | %87 |
| EI60 | 25 mm | %87 |
| EI90 | 32 mm | %85 |
| EI120 | 35 mm · 40 mm | %87 · %86 |
03 What to send
What information should you send for a quote?
Four details are enough to start; add the drawings if you have them.
- 01
Door location and building type
Stair, lobby, corridor or fire wall; hospital, hotel, office.
- 02
Required rating
The EI value if it is in the project; if not, the location is enough.
- 03
Size and quantity
Width, height and how many doors or partitions.
- 04
Opening and hardware
Number of leaves, fixed glass, panic bar, automation, colour.
04 FAQ
About glazed fire door prices
Rating and size affect the price most. Tell us both and the door's location; our technical team will work out the right system and hardware with you.
Why is the price of a glazed fire door not given as a single figure?
Fire rating, size, opening layout and hardware are determined together for each project; so the quote is prepared for the project once the technical scope is clear.
What is the difference between an EI60 and an EI90 door?
An EI90 door resists fire for longer and uses thicker glass: Polflam EI60 glass is 25 mm nominal, EI90 glass is 32 mm. In the Aliplast FR90 system doors are made up to EI90; FR65 door classes are EI30 and EI60.
Do I need architectural drawings for a quote?
If you have drawings or a section, the quote is finalised faster. If not, the door's location, rating, size and quantity are enough to start.
Do a panic bar and automation affect the price?
Hardware is one of the items in the quote: panic hardware, lock, door closer and automation are chosen together with the scope of the documents and listed separately in the quote.
→ Quote
Tell us about your doors and we will prepare the quote.
Location, rating, size and quantity: we will reply with a project-based quote.
- Phone
- +90 216 428 38 20
- abay@abayyapi.com
- Production
- Istanbul