01Product family

Glazed fire doors

A glazed fire door is a fire-rated door that, when closed, holds back flames and heat for a set time while keeping both sides visible and letting daylight through. Fire resistance does not come from the glass alone; the aluminium profile, glass, seals and hardware are tested together. We make these doors with Aliplast FR65 / FR90 profiles and Polflam glass, to each project's dimensions in Istanbul.

Fire resistanceEI30 – EI90
0306090120 min
Glazed fire door Turkey – double leaf with panic bars, aluminium frame Fire-resistant glassGets thicker with the rating Aluminium frame and leafThe frame around the glass Panic barOpens without a handle · BYKHY 47(5)
Double leaf · FR90Abay Yapı installation
System
Aliplast FR65 · FR90
Glass
Polflam, 20–35 mm
Types
Single, double, with side lights, sliding
Test
In the fire test, FR90 let no flame or smoke through for 103 minutes
Production
Made to measure in Istanbul for each project

01 Door types

Four types of glazed fire door.

Sizes shown are the system's maximum sizes (width × height). The size that can be used on a project is set by the size of the door in the fire test.

  1. Glass fire door Turkey – single leaf, Aliplast FR90
    01

    Single leaf

    For office and corridor entrances where a single-leaf opening is enough.

    1. Polflam glassEI30 20 mm · EI60 25 mm · EI90 32 mm
    2. FR90 frame and leaf90 mm profile
    3. Door closerSelf-closing device · BYKHY 47(3)
    4. Lever handleOpens by hand, never kept locked · BYKHY 47(2)
    Maximum size
    1,650 × 2,870 mm
    Document
    FR90 test report, ITB 2020
    Details
  2. Fire-rated door Turkey – double leaf in a stair lobby
    02

    Double leaf

    For stair lobbies and busy corridors that need a wide escape width.

    1. Panic barOpens in the escape direction without a lever handle · BYKHY 47(5)
    2. Door closer on each leafSelf-closing device · BYKHY 47(3)
    3. Meeting sealSmoke-tightness · BYKHY 47(3)
    4. Polflam glassEI30–EI90, 20–32 mm
    Maximum size
    3,170 × 2,870 mm
    Document
    EI60 classification report
    Details
  3. Glazed fire door Turkey – with fixed side and top lights
    03

    With side lights

    In wide openings it also glazes both sides and the top of the door, so the lobby reads as a single glass surface.

    1. Fixed side lightFixed glazing in a fire wall: at least half the wall's rating · BYKHY 25(2)
    2. Fixed top lightNo unrated opening left in the compartment line · BYKHY 24(7)
    3. Double-leaf doorSmoke-tight, self-closing · BYKHY 47(3)
    4. Panic barOpens in the escape direction without a lever handle · BYKHY 47(5)
    Building
    Door + fixed side and top lights
    Rule
    The fixed glazing is fire-rated too · BYKHY 25(2)
    Details
  4. Fire door Turkey – automatic sliding glazed type
    04

    Automatic sliding

    For hospital and building entrances that need continuous, hands-free passage.

    1. Motor boxThe mechanism that moves the leaves (FR90 Slide)
    2. Sliding leafEI30 (FR90 Slide) · EI60, E90 (Abay manufacture)
    3. Fixed side lightNo unrated opening left in the compartment line · BYKHY 24(7)
    Maximum size
    4,900 × 3,500 mm
    Class
    EI30 (FR90 Slide) · EI60 and E90 (Abay)
    Details

02 Fire resistance

The door's location decides how many minutes of fire resistance it needs.

EI30, EI60, EI90: the door resists fire for 30, 60 or 90 minutes. Choose a duration to see where the regulation requires it and which glass and system meet it.

EI120120 minutes in glass partitions →

Where does the regulation require it?

    Glass

    System

      In most of these locations the regulation also requires smoke-tightness (S) and self-closing (C). Both properties must also appear separately in the door's documents.

      Not only EI: we also make EW30 · EW60 · EW90 · EW120.

      EI

      The glass does not break in a fire; flames and smoke do not pass, and heat does not reach the other side.

      EW

      The glass does not break in a fire; flames and smoke do not pass, part of the heat reaches the other side, and radiation is limited.

      If your project calls for an EW class, we make EW doors and partitions for the same durations.

      Source: official BYKHY text. What do E, EW and EI mean?

      03 Profile system

      Which profile system: FR65 or FR90?

      We are Aliplast's authorised manufacturer and distributor for its fire-rated aluminium systems in Türkiye.

      Aliplast FR65Interior
      Aluminium fire door section Turkey – Aliplast FR65, 65 mm
      Frame / leaf
      65 / 65 mm
      Glass range
      17–25 mm
      Door rating
      EI30 · EI60
      Single leaf, maximum
      1,400 × 2,500 mm
      Double leaf, maximum
      2,690 × 2,500 mm
      Aliplast FR65
      Aliplast FR90Interior and exterior
      Aluminium fire door section Turkey – Aliplast FR90, 90 mm
      Frame / leaf
      90 / 90 mm
      Glass range
      20–69 mm
      Door rating
      EI30 · EI60 · EI90
      Single leaf, maximum
      1,650 × 2,870 mm
      Double leaf, maximum
      3,170 × 2,870 mm
      Aliplast FR90

      These values show the system's limits; the scope of the documents is checked separately for each size and class.

      Abay Yapı Sistemleri

      Trusted for 30 years.

      We make glazed fire doors with Aliplast profiles and Polflam glass in our Istanbul workshop, to each project's dimensions.

      154
      corporate references
      Aliplast
      authorised manufacturer and distributor in Turkey
      Polflam
      partner for fire-resistant glass
      Istanbul
      head office and production, Istanbul
      Glazed fire door project Turkey – double leaf with panic bars, side and top lightsGlazed fire door project Turkey – double leaf held open in a lift lobbyGlazed fire door project Turkey – stair front at a restaurant entranceGlazed fire door project Turkey – double leaf with side and top panelsGlazed fire door project Turkey – door and glass partition in a lift lobbyGlazed fire door project Turkey – black-framed door and glass partition in a corridor
      Lobby passage door · Double leaf · side and top lights
      1. 01Project and useBuilding type, required rating, door location
      2. 02Size and openingOverall size, clear width, opening direction
      3. 03System and hardwareProfile, glass, lock, closer
      4. 04Quote and productionScope agreed, delivered with the document set

      Projects

      Fire door and glass partition installations from our reference projects.

      Projects we have completed at office, hotel, restaurant and building exits. Tap a photo to enlarge it.

      04 Where it is used

      Where are glazed fire doors used?

      Choose a location to see how the door holds back fire and smoke there, and which properties the regulation requires.

      Fire-rated glass door Turkey – stair entrance Aluminium fire door Turkey – fire safety lobby entrance Fire door manufacturing Turkey – with side lights for a compartment crossing Glazed fire doors Turkey – hospital ward corridor Fire door manufacturers Turkey – hotel corridor smoke stop Glass fire door Turkey – exit with panic bar Fire side Escape side
      EIFire-rated30–90 min depending on location · BYKHY 47(3), 34(2)
      SSmoke-tightBYKHY 47(3), 34(2)
      CSelf-closingSelf-closing device · BYKHY 47(3)
      POpens without a handleOpens in the escape direction · BYKHY 47(5)
      Fire escape stair doorRequired at this location
      1. Fire escape stair door The door must be smoke-tight and self-closing. In a new building it must resist fire for at least 60 minutes if the stair serves fewer than 4 storeys, and at least 90 minutes if it serves a basement or more than 4 storeys. BYKHY 47(3)6090 Fire escape stair door page
      2. Fire safety lobby Placed in front of the escape stair, it keeps smoke away from the stair. It is separated from other areas by a smoke-tight door rated for at least 90 minutes, measures 3–6 m² and is kept clear. Where there is a firefighting lift, it opens into this lobby. BYKHY 34, 63(3)90 Fire safety lobby page
      3. Fire compartment crossing No unrated opening may be left between compartments. A door in a fire wall must resist fire for at least half the wall's rated duration. BYKHY 24(7), 25(2)Half the wall's duration Fire compartment page
      4. Hospital ward floors Ward floors larger than 300 m² are divided into at least two compartments. A glazed door between compartments keeps both sides visible as beds and staff pass through. BYKHY 49(1)(b), 24(7)Compartment line Hospital page
      5. Hotel corridors Escape doors in smoke-stop partitions are rated for at least 60 minutes and smoke-tight; guest room doors opening onto an internal corridor for at least 30 minutes. BYKHY 50(1)(b), 50(6)(a)3060 Hotel page
      6. Emergency exit door It opens in the direction of escape, is never kept locked and has a clear opening of at least 80 cm. At ground-level exits and on floors with more than 100 people, it opens without a lever handle, using a panic bar. BYKHY 47(1), 47(2), 47(5)Panic bar Emergency exit door page

      05 Document set

      Which documents should you ask for with a glazed fire door?

      Every door is delivered with a metal identification plate on it and its document set.

      Glazed fire door label Turkey – metal plate on the frame Metal plateClass · system · serial no · glass
      • Test reportFR90 single-leaf glazed doorITB (Poland), 2020 · Polflam 90 glassRequest
      • AuthorisationAliplast manufacturing authorisationAuthorised manufacturer and distributor in TurkeyRequest it
      • ClassificationFR90 double leaf, 60 minutesClassification report FIRES-CR-178-17-AUPERequest
      • DrawingFR65 / FR90 door sectionsDWGRequest

      Request the document set for your project. The test report and authorisation certificate are shared together with company and project details.

      Request the document set

      06 FAQ

      About glazed fire doors

      If your question is not here, ask our technical team.

      0216 428 38 20Send a question

      How long does a glazed fire door resist fire?

      30, 60 or 90 minutes, depending on the system and glass. The door's location decides which duration your project needs. For example, in a new building an escape stair door serving more than 4 storeys must be rated for at least 90 minutes.

      Source: BYKHY 47(3)

      Is a glazed fire door mandatory?

      The regulation does not require the door to be glazed. What it requires, depending on the door's location, is a fire resistance duration, smoke-tightness and self-closing. For example, escape stair and fire safety lobby doors are smoke-tight, self-closing and rated for 60 or 90 minutes. A glazed door meets these requirements while keeping light and visibility.

      Source: BYKHY 47(3), 34(2)

      Can a panic bar be fitted?

      Yes, with hardware covered by the test documents. Exit doors opening at ground level must open in the escape direction without a lever handle. Where more than 100 people are on a floor, the same rule applies to the escape stair, corridor and lobby doors on that floor.

      Source: BYKHY 47(5)

      Do the doors have to be self-closing?

      Escape stair and fire safety lobby doors are fitted with a self-closing device.

      Source: BYKHY 47(3)

      What is the difference between a fire-rated door and a glazed fire door?

      Both stop fire for a set time. A sheet metal, steel or timber fire-rated door does not let light through. A glazed fire door achieves the same duration with an aluminium profile and fire-resistant glass, keeping light and visibility in corridors, lobbies and entrances.

      What determines the price of a glazed fire door?

      Door type, size, required fire resistance duration (which sets the glass thickness), hardware (panic bar, door closer, automation), quantity and installation conditions. Share the size and location and we will prepare a quote within the scope of the documents.

      What determines the price

      → Quote

      Share the door's location and size.

      Our technical team will identify the right type, class and document set and get back to you. If you have a project file, you can also send it by email.

      Call · 0216 428 38 20Email

      Production
      Istanbul

      Quote form* required field

      CallRequest a quote