KFire criteria · regulation

Fire door requirements

A fire door, when closed, resists the passage of smoke, heat and flame for a set time. How many minutes that time must be, and whether the door must be smoke-tight or self-closing, is set by the Turkish Fire Regulation (BYKHY) according to where the door is: 30 minutes for a hotel room door, 90 minutes for a boiler room, for example.

Fire resistance by location30 – 90 min
0306090120 min
Fire door requirements Turkey – doors in the building core Stair doorThe number of storeys sets the duration Floor doorFire behind the glass
Building coreEach door's duration is set by its location
Fire resistance
30 · 60 · 90 min
Deciding factor
Door location
Stair
New / existing building
Regulation
BYKHY

01 Your door

How many minutes must your door resist fire?

Choose the door's location; the duration, properties and article the regulation requires will appear.

Neighbouring buildingBoiler room · basementStair
Tap a number; location names are below.

Where is the door? Tap a number on the section or the list.All locations

Fire door requirements Turkey – stair door Fire door requirements Turkey – lobby door Fire door requirements Turkey – compartment door Fire door requirements Turkey – door in a shared wall Fire door requirements Turkey – hotel smoke-stop partition Fire door requirements Turkey – boiler room entrance Fire door requirements Turkey – external passage door Fire side Escape side
01Escape stairOrange door in the section

The final class is set by the project designer, the fire consultant and fire brigade approval. This tool is guidance, not legal advice.

02 All locations

How many minutes must a door resist fire in each location?

Nine rows in one table; each row states what the article explicitly requires. EI30 · EI60 · EI90 · EI120

Door locationFire resistanceWhat the article requiresBYKHY
Escape stair (new building)At least 60 or 90 minSmoke-tight, self-closing47(3)
Escape stair (existing building)At least 60 or 90 minSmoke-tight, self-closing157(1), 157(3)
Fire safety lobbyAt least 90 minSmoke-tight, self-closing34(2), 47(3)
Boiler room exitAt least 90 minSmoke-tight, self-closing54(5)
Door in a fire wallAt least half the wall's durationSmoke-tight, self-closing25(2)
Compartment boundaryAt least 60 minSmoke- and heat-tight boundary4(1)(tt), 24(7)
Smoke-stop door in a hotel corridorAt least 60 minSmoke-tight, self-closing50(6)(a), 50(6)(c)
Hotel room to internal corridorAt least 30 minSelf-closing50(1)(b)
Exit onto an external passageAt least 30 minSelf-closing37(2)

03 Letters on the certificate

What do the letters E, I, S and C on a fire door certificate mean?

The regulation's durations are written on the certificate with these letters and the minutes, for example EI60 S C. The difference between E, EW and EI

  1. E

    Flame-tight

    Throughout the fire, the door stops flames and hot gases passing to the other side.

  2. I

    Blocks heat

    The surface on the escape side does not heat up either, so people passing it are protected. EI shows both together.

  3. S

    Smoke-tight

    When closed, smoke does not pass around the edges or between the leaves.

  4. C

    Self-closing

    The door closer shuts the door every time; it does not stay open.

04 Responsibility

What happens if a fire door does not comply with the regulation, and who is responsible?

Two articles bind every stage of the project.

  1. BYKHY 5(1)

    Building permit and occupancy permit

    If the design does not comply with the regulation, no building permit is issued. If a new building is found not to have been built in compliance, no occupancy permit is issued until the deficiencies are remedied.

  2. BYKHY 6(1)

    Responsible parties

    The permit-issuing authority, investor, building owner, employer, the architects and engineers in design and construction, contractor, manufacturer and building inspection.

Abay Yapı Sistemleri

Trusted for 30 years.

We manufacture the fire door and glass partition each location requires with Aliplast profiles and Polflam glass in our Istanbul workshop.

154
corporate references
Aliplast
authorised manufacturer and distributor in Turkey
Polflam
partner for fire-resistant glass
Istanbul
head office and production, Istanbul
Fire door requirements project Turkey – double leaf with panic bars, side and top lightsFire door requirements project Turkey – door and glass partition in a lift lobbyFire door requirements project Turkey – black-framed door and glass partition in a corridorFire door requirements project Turkey – double leaf with side and top panels
Lobby passage door · Double leaf · side and top lights
  1. 01Project and useBuilding type, required rating, door location
  2. 02Size and openingOverall size, clear width, opening direction
  3. 03System and hardwareProfile, glass, lock, closer
  4. 04Quote and productionScope agreed, delivered with the document set

Projects

Doors from our reference projects in the locations the regulation covers.

Work we have completed on stairs, lobbies, escape exits and compartment boundaries. Tap a photo to enlarge it; browse with the arrows.

05 Document set

Which document shows that the door meets the requirement?

The duration and properties the regulation requires must appear in the door's own classification report and declaration of performance.

Four checks at handover

  1. Fire resistance. The minutes in the report must not be less than the duration the door's location requires.
  2. S and C. If the location requires smoke tightness or self-closing, these letters must appear on the certificate.
  3. Type and size. The door tested in the report must be the same type as the project door and no smaller.
  4. Declaration and CE. The declaration of performance and CE marking must be issued for the door itself.
  • ClassificationThe door's classification reportMatching the type and size of the door in the projectRequest it
  • DeclarationDeclaration of performanceCE markedRequest it
  • AuthorisationAliplast manufacturing authorisationAuthorised manufacturer and distributor in TurkeyRequest it

Source: Turkish Construction Products Regulation 6(1), 10(2)

Ask for your project's document set. Document details: for the fire brigade and occupancy permit.

Request the document set

06 FAQ

About fire door requirements

The final class is set by the project designer, the fire consultant and fire brigade approval. Ask us how it applies to your project.

0216 428 38 20Send a question

What is a fire door?

Under the regulation, a fire door is a door, hatch or shutter that, when kept closed, resists the passage of smoke, heat and flame for a set time. That time varies with the door's location.

Source: BYKHY 4(1)(şş)

How many minutes must a fire door resist fire?

There is no single duration; the door's location decides. A door from a hotel room to the corridor resists fire for at least 30 minutes, a compartment boundary for at least 60, and a fire safety lobby or boiler room door for at least 90 minutes. An escape stair door is 60 or 90 minutes, depending on the building.

Source: BYKHY 50(1)(b), 4(1)(tt), 34(2), 54(5), 47(3)

What is a fire compartment?

An area within a building separated smoke- and heat-tight on every side, ceiling and floor included, by elements resisting fire for at least 60 minutes. No unrated opening may be left between compartments.

Source: BYKHY 4(1)(tt), 24(7)

What is a high-rise building?

A building more than 21.50 m high above ground and more than 30.50 m in total height. In existing buildings, the 30.50 m limit also decides whether the stair door must resist fire for 60 or 90 minutes.

Source: BYKHY 4(1)(ccc), 157(1)

What happens if a compliant fire door is not installed?

If the design does not comply with the regulation, no building permit is issued. If a new building is found not to have been built in compliance with the regulation, no occupancy permit or operating licence is issued until the deficiencies are remedied.

Source: BYKHY 5(1)

Who is responsible for the fire door?

The permit-issuing authorities, investors, building owners, employers, the architects and engineers in design and construction, contractors, manufacturers and building inspection are responsible for applying the regulation.

Source: BYKHY 6(1)

Must a smoke-tight door be single-leaf?

It can be single- or double-leaf. It must be self-closing, the leaves must close the opening completely, and the gap between leaf and floor must not exceed 4 mm.

Source: BYKHY 50(6)(c)