03Door type · one of 4 types
Glazed fire door with side lights
A glazed fire door with side lights closes one or both sides of the door, and the top if needed, with fire-resistant glass that does not open (fixed glazing); the door provides passage, the fixed glazing provides light and vision. The regulation requires the door and fixed glazing in a fire wall to resist fire for at least half the wall's rating.
Top lightCloses the top of the door
Side lightIn the regulation: fixed light window
Panic barBYKHY 47(5)
- Layout
- Door + one or two side lights
- FR90 classes
- Door EI30–EI90 · fixed glazing EI30–EI120
- FR65 classes
- Door and fixed glazing EI30 · EI60
- Glass
- Polflam fire-resistant glass, 20–40 mm
- Rule
- Half the wall rating in a fire wall
01 Layouts
Which layouts are available for a door with side lights?
There are two layouts: a door with one side light, or a door with two side lights. The central door can be single-leaf or double-leaf. Choose a layout.
Door + side light. A layout that combines a vision panel with a door. The fixed glazing sits on one side of the door.
Door + two side lights. Used at corridor and compartment crossings. The door stays in the centre with glass on both sides.
Double-leaf + two side lights. A single-leaf exit door cannot give a clear opening wider than 120 cm (BYKHY 33(5)); a wider opening is given with two leaves, again with fixed glazing on both sides. For the leaves, see the double-leaf page.
Clear width is measured at the door: between the frame and the leaf opened to 90 degrees; on a double-leaf door, between the two open leaves. Fixed glazing does not count towards this width BYKHY 33(5)
02 Components
What parts make up a door with side lights?
Tap the numbers: which part opens, which stays fixed and what the regulation requires of each.
- Door leafThe single part that opens; it provides the passage. Clear width is measured between the frame and the leaf opened to 90 degrees. In the Aliplast listing, the FR90 door is EI30–EI90 and the FR65 door EI30–EI60.BYKHY 33(5)
- Side lightDoes not open; the regulation calls it a fixed light window. In a fire wall, it resists fire for at least half the wall's rating.BYKHY 25(2)
- Top lightCloses the opening above the door. In Aliplast FR90, fixed glazing is listed up to class EI120.
- Panic barOpens the door with a push, without turning a lever handle. Required on escape doors opening at ground level to a safe area, and on stair, corridor and lobby doors of floors holding more than 100 people.BYKHY 47(5)
- Door closerCloses the leaf again once released. Self-closing is mandatory for doors in a fire wall and for exit doors opening onto an internal escape corridor or an external passage.BYKHY 25(2), 36(1)(b), 37(2)
The door leaf and the fixed glazing have separate fire documents; both are required in the document set.
03 Fire resistance
How many minutes must the door and fixed glazing in a fire wall resist?
The fire wall article names the door and the fixed light window together. There is also a separate rule for openings between fire compartments. Choose the wall.
At least 45 minutes
- Aliplast classes are 30, 60 and 90 minutes; the first to meet 45 minutes is EI60.
- The door is self-closing and smoke-tight.
- The surroundings of these openings are kept clear of all combustible materials.
At least 60 minutes
- If the wall is rated 120 minutes, half is 60; among the Aliplast classes, EI60 meets it.
- The door is still self-closing and smoke-tight.
- No combustible material is left around the openings.
Non-fire-rated openings are not permitted
- Every side of a compartment is separated by building elements fire-rated for at least 60 minutes.
- This rating is continuous at the junctions as well.
- No non-fire-rated opening is permitted between compartments.
"Where openings such as doors and fixed light windows in walls cannot be avoided, they must be fire-resistant for at least half the fire resistance period of the fire wall."
Turkish Fire Regulation (BYKHY), Article 25(2)
Abay Yapı Sistemleri
Trusted for 30 years.
We manufacture the door and its fixed glazing together as one system, with Aliplast profiles and Polflam glass, in our workshop in Istanbul.
- 154
- corporate references
- Aliplast
- authorised manufacturer and distributor in Turkey
- Polflam
- partner for fire-resistant glass
- Istanbul
- head office and production, Istanbul





- 01Project and useBuilding type, required rating, door location
- 02Size and openingOverall size, clear width, opening direction
- 03System and hardwareProfile, glass, lock, closer
- 04Quote and productionScope agreed, delivered with the document set
Projects
Doors with side and top lights from our reference projects.
Our installations where the door joins side or top glazing. Open a photo and browse with the arrows.
04 System and class
How many minutes does a door with side lights resist fire?
In Aliplast FR90, fixed glazing is classified up to 120 minutes and the door up to 90. FR65 is for interiors only, up to 60 minutes. Tap the required duration.
At 60 minutes, both systems cover the door and the fixed glazing; this is the highest class in the FR65 listing.
FR65: door and partition EI30 / EI60. FR90: door EI30 / EI60 / EI90, partition EI30–EI120. The class of the whole assembly is confirmed by the joint classification of glass and profile.
05 Where it is used
Where is a door with side lights used?
Four example locations. The fixed glazing brings daylight and vision into the escape route; in a fire, the door closes and the fire stays on the other side of the glass. Each shows the regulation article that applies to the door.
Fire side
Escape side
- Exit to an external escape passage An exit door opening from an internal corridor onto an external escape passage is fire-rated for 30 minutes and self-closing. In the scene, the fire is in the corridor behind the wide fixed glazing; the passage outside is free of smoke. BYKHY 37(2)30 Emergency exit door page
- From an office to an escape corridor An exit door opening onto an internal escape corridor has the same rating as the escape stair door and is self-closing. The wide fixed glazing on both sides of the door carries daylight from the office into the corridor. BYKHY 36(1)(b)Equal to the stair Emergency exit door page
- Compartment crossing in a hospital In a hospital, an inpatient floor larger than 300 m² is divided into at least two compartments, or a protected horizontal evacuation area is provided. No non-fire-rated opening is permitted between compartments. BYKHY 49(1)(b), 24(7)No non-rated openings Hospital page
- Opening in a fire wall A fire wall separating two adjoining buildings resists fire for at least 90 minutes. The door and fixed light window in it resist for at least half of that; the door is self-closing and smoke-tight. BYKHY 25(1), 25(2)Half the wall Fire wall door page
06 Document set
Which documents should you request for a door with side lights?
A fire test carried out on fixed glazing is not valid for a glazed door. If the project has both a door and fixed glazing, a separate document is provided for each.
Four checks in a quote
- Two separate reports. The document for the door and for the fixed glass partition are requested separately.
- Size. The door, fixed partition and glass in the test must not be smaller than those in the project.
- Glass brand. The fire-resistant glass used in the test is the glass used in the project; check the glass label and the etched stamp in its corner.
- Manufacturing authorisation. A manufacturer producing in Turkey must hold a manufacturing authorisation from the certified system owner.
- DoorSingle- or double-leaf door reportFire class of the central doorRequest
- Fixed glazingFixed glass partition reportGlass beside and above the door · does not replace the door reportRequest
- AuthorisationAliplast manufacturing authorisationAbay's authorisation to manufacture FR65 / FR90Request
- Glass documentPolflam fire-resistant glassThe glass's own document · does not replace the framing reportRequest
Request both reports together. Documents are shared with company and project details.
Request the document set07 FAQ
About fire doors with side lights
If your question is not here, ask our technical team.
What is a fire door with side lights?
It is a layout with fire-resistant glass that does not open on one or both sides of the door, and sometimes above it. The door provides passage; the fixed glazing closes the rest of the opening against fire and gives light and vision.
Must fixed glazing in a fire wall also be fire-rated?
Yes. Openings in a fire wall, such as doors and fixed light windows, must resist fire for at least half the wall's rating. No non-fire-rated opening is permitted between fire compartments either.
Source: BYKHY 25(2), 24(7)
How many minutes should the door and glass in a fire wall be rated for?
A fire wall resists fire for at least 90 minutes; the door and fixed glazing in it must meet half of that, i.e. at least 45 minutes. As Aliplast door classes are 30, 60 and 90 minutes, EI60 is the one that meets 45 minutes. The door must also be self-closing and smoke-tight.
Source: BYKHY 25(1), 25(2)
What is the maximum fire rating for fixed glazing?
In the Aliplast FR90 system, fixed glazing is made up to class EI120 using 35 or 40 mm Polflam EI120 glass. In the same system, the door is listed up to EI90.
Does fixed glazing count towards the escape width?
No. On an exit door, the width is measured between the frame and the leaf opened to 90 degrees; on a double-leaf door, between the two open leaves. As fixed glazing does not open, it is not included.
Source: BYKHY 33(5)
Is the door's fire report also valid for the side light?
Whichever of single door, double door and fixed glass partition the project includes, a separate document is provided for each. A test carried out on fixed glazing is not valid for a glazed door.
What determines the price of a door with side lights?
The overall size of the opening, whether there are one or two side lights, a top light, the required duration (which sets the glass thickness), the profile system and the door hardware. Send us the opening size and wall type, and we will prepare a quote that fits the scope of both reports.
→ Quote
Share the size of the opening.
Our technical team will define the system, rating and document set and get back to you. You can also email your project file.
- Phone
- +90 216 428 38 20
- abay@abayyapi.com
- Production
- Istanbul