01Partition type · one of 3 types
Framed fixed glass partition
A framed fixed glass partition divides large fire-resistant glass panes with vertical and horizontal aluminium profiles to form a non-opening, floor-to-ceiling fire-rated wall. It is classified up to 60 minutes with Aliplast FR65 and up to 120 minutes with FR90. It keeps light and visibility on the corridor, stair and compartment lines where the regulation requires a fire-resistant wall.
Fire-resistant glassNon-opening
Vertical intermediate profileHolds the panes side by side
Bottom frameConnects the partition to the floor
- Profile
- Aliplast FR65 · FR90
- Partition rating
- FR65 EI30–60 · FR90 EI30–120
- Glass
- Polflam, 20–40 mm
- Glass range
- FR65 17–25 · FR90 20–69 mm
- Tested partition
- FR90: 6,000 × 3,000 mm
01 Sizes
What sizes can a fixed glass partition be made in?
The partition is drawn to the same scale as a 1.75 m tall person. Switch between the system's three sizes. The glass layout is set on the project; the drawing shows the overall size only.
02 Components
What parts make up a fixed glass partition?
Three views change in turn; the line at the top shows the move to the next one. Tap the view you want, and tap the numbers to examine the parts.
1 / 3 · General viewThe partition separates the protected corridor from the hall burning behind it.
- Fire-resistant glassDoes not open; gives light and visibility. Its thickness is chosen for the required duration.
- Vertical intermediate profileHolds two panes side by side.
- Horizontal intermediate profileDivides the glass panes in height.
- Perimeter frameConnects the partition to the wall, floor and ceiling.
2 / 3 · Wall and ceiling junctionThe edge of the partition: the perimeter frame joins the wall, ceiling and floor.
- Wall junctionThe perimeter frame is fixed to the side wall.BYKHY 24(7)
- Ceiling junctionThe head frame is fixed to the ceiling.BYKHY 24(7)
- Floor junctionThe sill frame sits on the floor.
3 / 3 · Glass and profileThe partition from the front: two panes enter the central profile, their edges stay inside the profile.
- Fire-resistant glassPolflam glass; 20–40 mm thick depending on duration. Its edge stays inside the profile and is not visible from outside.
- Vertical profileAluminium intermediate profile; 65 mm deep in FR65, 90 mm in FR90.
- GasketPresses on both faces of the glass. Glass, profile, gasket and accessories are assessed together.
03 Fire resistance
How many minutes does a fixed glass partition resist fire?
Tap the required duration to see which profile system meets it and the glass thickness. How many minutes are needed depends on the wall the partition sits in: duration by wall.
FR65 partition EI30 / EI60; FR90 partition EI30 / EI60 / EI90 / EI120, door up to EI90. The partition's class is verified by the joint classification of glass and profile.
Abay Yapı Sistemleri
Trusted for 30 years.
We manufacture fixed glass partitions with Aliplast profiles and Polflam glass in our Istanbul workshop, to each project's dimensions.
- 154
- corporate references
- Aliplast
- authorised manufacturer and distributor in Turkey
- Polflam
- partner for fire-resistant glass
- Istanbul
- head office and production, Istanbul



- 01Project and useBuilding type, required rating, door location
- 02Size and openingOverall size, clear width, opening direction
- 03System and hardwareProfile, glass, lock, closer
- 04Quote and productionScope agreed, delivered with the document set
Projects
Framed glass partitions from our reference projects.
The top row shows our framed fixed partitions, the bottom row doors installed on the same line. Tap to enlarge, use the arrows to browse.
04 Junctions
What needs attention at the junctions?
A glass wall is protected not only in its middle but also where it meets the wall, ceiling and services. Three rules from the Turkish Fire Regulation (BYKHY):
Junction points
The fire resistance of the elements enclosing a compartment continues at their junctions; there can be no unrated openings between compartments.
BYKHY 24(7)No combustible material around it
The surroundings of openings in a fire wall, such as doors and fixed vision panels, are kept free of all combustible material.
BYKHY 25(2)Service penetrations
If water, electrical, heating or ventilation services pass through a fire wall or floor, the gap around them is sealed, leaving no opening, for at least the wall's or floor's fire resistance time.
BYKHY 25(2), 26(5)
05 Where it is used
Where are fixed glass partitions used?
A framed partition is used where the regulation requires a fire-resistant wall and visibility and daylight are also needed. In each scene the fire is on the other side of the glass.
Fire side
Safe side
- Protected escape corridor A protected corridor serving as an escape route is separated from adjacent spaces by fire-resistant building elements; the fire resistance time follows Tables Annex 3/B and Annex 3/C of the regulation. In the scene a laboratory is on fire, while the corridor on this side of the glass is free of smoke. BYKHY 4(1)(dd), 36(1)(a)Annex 3/B, 3/C
- Escape stair enclosure A protected stair is enclosed with a fire-resistant material. In the scene the floor is fully on fire; the stair enclosure on this side of the framed glass is clear. BYKHY 4(1)(ee)Protected Escape stair door page
- Wall separating a production hall Elements separating a compartment, including ceiling and floor, resist for at least 60 minutes; no unrated opening is left between compartments. The office sees the hall through the glass, and the fire stays in the hall. BYKHY 4(1)(tt), 24(7)60 Factory and warehouse page
- Main electrical room The walls of enclosed areas with a fire hazard, such as main electrical distribution rooms, transformer rooms and generator rooms, have the properties of a compartment wall. The control room sees the panels through the glass; a fire in a panel stays in the room. BYKHY 24(2)Compartment wall
06 Document set
Which documents should you ask for with a fixed partition?
A fire test carried out on the partition does not apply to a glazed door on the same line. If the partition contains a door, the two documents are requested separately.
Four checks in a quote
- The partition's report. The class is shown by the fixed partition's own classification report; the glass certificate does not replace it.
- Size. The partition and glass pane tested in the report must not be smaller than those on the project.
- Glass brand. The project uses the fire-resistant glass used in the test; the glass label and the etched stamp in its corner are checked.
- Manufacturing authorisation. The company manufacturing the partition in Turkey must hold a manufacturing authorisation from the certified system owner.
- ClassificationFixed partition reportFire class of the FR65 / FR90 partitionRequest it
- Glass certificatePolflam fire-resistant glassThe glass's own declaration · does not replace the partition reportRequest it
- AuthorisationAliplast manufacturing authorisationAuthorised manufacturer and distributor in TurkeyRequest it
- DrawingFR65 / FR90 partition sectionsDWGRequest it
Request the partition's document set. The report and manufacturing authorisation are shared with company and project details.
Request the document set07 FAQ
About fixed glass partitions
If your question is not here, ask our technical team.
How many minutes does a framed fixed glass partition resist fire?
30 or 60 minutes with Aliplast FR65; 30, 60, 90 or 120 minutes with FR90. Which duration is needed depends on the wall the partition sits in; for example, the elements enclosing a fire compartment resist for at least 60 minutes.
Source: BYKHY 4(1)(tt)
How large can a fixed glass partition be?
For an FR65 partition, up to 4,930 × 3,104 mm in the 30-minute class and 4,930 × 2,904 mm at 60 minutes. With FR90 the fire-tested fixed partition is 6,000 × 3,000 mm. The size that can be used on a project is set by the field of application in the partition's report.
How does the partition join the wall and ceiling?
On a compartment line, the regulation requires the fire resistance of the enclosing elements to continue at their junctions and does not allow unrated openings between compartments. The point where the partition joins the wall and ceiling is designed as part of this continuity.
Source: BYKHY 24(7)
What happens if services pass through the partition line?
If water, electrical, heating or ventilation services pass through a fire wall or floor, the gap around them is sealed against the passage of fire and smoke, leaving no opening, for at least the fire resistance time of the wall or floor.
Source: BYKHY 25(2), 26(5)
FR65 or FR90?
FR65 is used indoors and reaches up to 60 minutes as a partition; profile depth 65 mm, glazing range 17–25 mm. FR90 is used indoors and outdoors and reaches up to 120 minutes as a partition; depth 90 mm, glazing range 20–69 mm.
What determines the price of a fixed glass partition?
The partition's length and height, the required duration (the glass thickness depends on it), the profile system, the glass layout, whether the partition contains a door, and installation conditions. Send us the size and the wall the partition sits in, and we will prepare a quote within the scope of the report.
→ Quote
Tell us the partition's size.
Our technical team will determine the profile system, glass thickness and document set and get back to you. If you have a plan or elevation drawing, send it by email.
- Phone
- +90 216 428 38 20
- abay@abayyapi.com
- Production
- Istanbul