C3Fire criteria · location

Fire compartment

A fire compartment is a part of a building separated on every side, including its ceiling and floor, by walls and floor slabs rated for at least 60 minutes, and it keeps out smoke and heat. Doors and glass in the boundary are fire-rated too. How large it may be depends on the building's use: at most 8,000 m² in offices, 1,500 m² in hospitals.

Fire compartment Turkey – glass partition closing off an office corridor Compartment lineWall-to-wall glass partition Door in the lineClosed, fire on the other side
Compartment lineDoor and glass partition together
Fire resistance of the boundary
At least 60 minutes
Largest area in offices
8,000 m²
Hospital in-patient floor
Over 300 m²: split in two
In high-rise buildings
At most 3 storeys
Door and glass in the boundary
Fire-rated

01 Largest area

What is the maximum size of a fire compartment in m²?

The compartment area is the floor area of the section enclosed by fire-rated walls and floor slabs. If a floor is larger than this limit, it is divided by fire-rated lines running from external wall to external wall. Choose your building and enter the floor area; the plan divides itself.

1What is the building used for?

2compartmentsminimum · this floor

In an office building a compartment is at most 8,000 m² (≈ 89 × 89 m).

With fire control systems such as detection and sprinklers, the limit is 16,000 m²: the floor can be a single compartment.

Source: BYKHY 24(6), Annex 4

1234567891011ABCDE166.0 m72.3 mFLOOR PLAN · +3.50020 mKA · 6,000 m²B · 6,000 m²
One compartmentCompartment wall · fire-rated min. 60 minEscape stair

02 Line on the plan

Where does the compartment line run on the plan?

Example: a 12,000 m² office floor divided into A and B because the limit is 8,000 m². Choose a rule; its location is marked on the plan.

Uninterrupted from façade to façade

The line runs without interruption from one external wall to the opposite external wall and from floor to ceiling; it is fire-rated at the junctions too. On a curtain wall, the junction between façade and floor slab is insulated for the slab's rating.

ExampleIn an office with a glass façade the line runs right up to the façade; no open joint is left where the façade meets the partition.

Source: BYKHY 24(7), 27(3)(a)

1234567891011ABCDE166.0 m72.3 mFLOOR PLAN · +3.50020 mKAB12345
Compartment wallGlass partitionEscape routeDuct

03 Boundary line

What requirements apply at the compartment boundary?

First the line itself, then its junctions with ceiling, wall and floor; tapping a tab locks the view.

Fire compartment boundary Turkey – glass wall dividing an open-plan office

1 / 2 · Boundary lineThe fire in the neighbouring compartment is fully developed; this side is calm. The line keeps the fire in its own section.

Resistance≥ 60 minOpeningFire-rated

  1. Glass wallThe separating element is rated for at least 60 minutes; the glazed partition carries this class with its certification.
  2. DoorThere can be no non-fire-rated opening between compartments; the door in the line is fire-rated too.
  3. Ceiling slabA compartment is separated on every side, including its ceiling and floor slabs; the line rises to the slab.

Source: BYKHY 4(1)(tt), 24(1), 24(7)

04 Where in the building

Where does the compartment boundary run in the building?

Section A-A: a 10-storey office building with a basement. The stair and lift shaft form a separate protected core, and the compartments lie outside it. Choose a rule; that compartment appears in orange on the section.

A compartment is a box

A compartment is enclosed not only by walls but also by the floor slabs below and above it. All six faces are rated for at least 60 minutes; all floor slabs have the quality of a fire wall.

ExampleIf an office floor is a compartment, its floor and ceiling are also part of the boundary; fire does not pass to the floor below or above.

Source: BYKHY 4(1)(tt), 26(1)

±0.00+3.50+7.00+10.50+14.00+17.50+21.00+24.50+28.00+31.50+35.00−4.5021.50 mSECTION A-Aone compartment12345
One compartmentBoundary · fire-rated min. 60 minReinforced concrete sectionStair well

05 Four locations

Where is a compartment line most often built?

Four locations, and in all four the door and glass in the line are fire-rated. Tap a location and the properties the article requires light up.

Fire compartment Turkey – large open-plan office floor Fire compartment Turkey – hospital ward floor Fire compartment Turkey – enclosed car park and lift lobby Fire compartment Turkey – between office lobby and shop Fire side Safe side
60Rated for at least 60 minutesBYKHY 4(1)(tt)
60+At least REI 60, more depending on heightBYKHY Annex 3/B, Annex 3/C
EIDoor and glass in the line are fire-ratedBYKHY 24(7)
m²A floor is divided when the area limit is exceededBYKHY 24(6), Annex 4
½The floor is divided into parts at least half its sizeBYKHY 49(1)(b)
Line dividing a large open-plan officeRequired here
  1. Line dividing a large open-plan office In an office building, if a floor exceeds 8,000 m² (16,000 m² with suitable fire control systems), the open-plan office is divided by a line rated for at least 60 minutes; the door and glass in the line are fire-rated too. BYKHY 24(6), 24(7), Annex 460 Office building page
  2. Line splitting a hospital ward floor in two In hospitals and care homes, every in-patient floor larger than 300 m² is divided into two or more compartments, each at least half the floor's size, or a protected horizontal evacuation area is provided. Patients move away from the fire into the neighbouring compartment on the same floor. BYKHY 49(1)(b), 4(1)(s)60 Hospital page
  3. Car park door to the lift lobby The walls and floor slabs of car parks, boiler rooms, main electrical rooms, transformer and generator rooms have the quality of compartment walls. The door from such a space into the building is fire-rated too. BYKHY 24(2), 24(7)60
  4. Between a shop and an office lobby A compartment wall separating different uses within a building is rated for at least REI 60 or the duration in Annex 3/C for the building class and height, whichever is greater. BYKHY Annex 3/B, Annex 3/C, 24(7)60+ Shopping centre page

06 Your project

Where should the compartment line run in your project?

These four answers change the line's location and rating.

  1. 01

    What is the building's use?

    8,000 m² in offices, 4,000 in hotels, 1,500 in hospitals; in mixed use the uses are also separated from each other.

  2. 02

    Is there a fire control system?

    With detection, sprinklers and smoke extraction, the area doubles or becomes unlimited.

  3. 03

    How tall is the building in metres?

    In a non-residential building over 21.50 m, the upper floors form compartments of at most three storeys each; the rating rises with height.

  4. 04

    Is there a door or glass in the line?

    Every opening between compartments is fire-rated; the door and glass are chosen to match the line's rating.

Let us specify the glass and door in your compartment line together. Send the plan and building details; our technical team will review them.

Send the project

07 Boundary in glass

Can we build the compartment boundary in glass?

We make it with Aliplast profiles and Polflam glass to the line's rating and dimensions.

  1. Framed partition

    EI30 – EI120

    Floor-to-ceiling, non-opening glass wall; up to 60 minutes with FR65, 120 minutes with FR90. Fixed glass partition

  2. Frameless partition

    Uninterrupted glass

    Without vertical profiles, 30–120 minutes with Polflam BR glass. Frameless glass partition

  3. Door in the line

    Single or double leaf

    FR65 and FR90 glazed doors are also made in class EI60. Double leaf

The class is given by a certificate in which glass and profile were tested together; the partition height and glass size stay within the scope of the certificate. Fire-rated glass partition

Abay Yapı Sistemleri

Trusted for 30 years.

We make the glass partitions and doors for compartment lines with Aliplast profiles and Polflam glass, to each project's dimensions in our Istanbul workshop.

154
corporate references
Aliplast
authorised manufacturer and distributor in Turkey
Polflam
partner for fire-resistant glass
Istanbul
head office and production, Istanbul
Fire compartment project Turkey – glass partition and glazed doors in a stair hallFire compartment project Turkey – glass partition and door enclosing a meeting roomFire compartment project Turkey – double leaf with panic bars, side and top lights
Stair hall · Glass partition
  1. 01Project and useBuilding type, required rating, door location
  2. 02Size and openingOverall size, clear width, opening direction
  3. 03System and hardwareProfile, glass, lock, closer
  4. 04Quote and productionScope agreed, delivered with the document set

Projects

Glass partition and door lines from our reference projects.

Top row: our glass partition installations; bottom row: passage doors in the line. Tap a photo; browse with the arrows.

08 Document set

Which documents are required for the glass and door in a compartment line?

The line's fire resistance is shown with separate documents for the partition and the door.

Four checks at handover

  1. Fire resistance. The minutes in the report must not be less than the duration the line requires.
  2. Partition and door separately. The glass partition and the door in the line must each have their own classification report.
  3. Size. The partition height and glass size must stay within the scope of the report.
  4. Declaration and CE. A declaration of performance issued for the product and the CE marking are required.
  • ClassificationPartition classification reportWith the project's height and glass sizeRequest
  • ClassificationDoor classification reportSingle or double leafRequest
  • DeclarationDeclaration of performanceCE markedRequest it
  • DrawingCeiling, wall and floor junction detailsDWGRequest

Source: Turkish Construction Products Regulation 6(1), 10(2)

Request the document set for the compartment line. Documents are sent together with the line's rating and dimensions.

Request the document set

09 FAQ

About fire compartments

The compartment line and its rating are set by the project architect, the fire consultant and fire brigade approval. These articles are a starting point; let us draw together where the line will run in your project.

0216 428 38 20Send a question

What is a fire compartment?

A part of a building separated on every side, including its ceiling and floor slabs, by building elements rated for at least 60 minutes, which keeps out smoke and heat. It keeps a fire in the section where it started; people escape by moving to the neighbouring compartment.

Source: BYKHY 4(1)(tt), 4(1)(s)

What is the maximum size of a fire compartment in m²?

It depends on the building's use: 8,000 m² in offices, 4,000 in hotels, 1,500 in hospitals, 2,000 in commercial buildings, 6,000 in educational facilities. With suitable fire control systems the area can be doubled in offices, hotels and hospitals, and is unlimited in commercial and educational buildings.

Source: BYKHY 24(6), Annex 4

How many minutes must a compartment wall resist fire?

At least 60 minutes. A wall separating different uses is rated for REI 60 or the duration in Annex 3/C, whichever is greater. For example, in an office building without sprinklers, 60 minutes if the building height is below 21.50 m, 90 minutes if below 30.50 m.

Source: BYKHY 4(1)(tt), Annex 3/B, Annex 3/C

Can there be a door or glass in the compartment boundary?

There can be no non-fire-rated opening between compartments, and the fire resistance of the enclosing elements is continuous at the junctions too. So the door and glass partition in the line are fire-rated and carry the line's rating with their certification.

Source: BYKHY 24(7)

What is the difference between a fire compartment and a fire wall?

A compartment is a section within a building, with a boundary rated for at least 60 minutes. A fire wall separates adjoining (terraced) buildings from each other and is rated for at least 90 minutes; doors and fixed glazing in it are rated for at least half the wall's rating, and its door is self-closing and smoke-tight.

Source: BYKHY 4(1)(tt), 25(1), 25(2)

How are compartments arranged in a high-rise building?

In non-residential buildings taller than 21.50 m and residential buildings taller than 30.50 m, the floors above these heights are arranged with at most three storeys per fire compartment.

Source: BYKHY 24(4)

What should a fire compartment be like in a hospital?

Every in-patient floor larger than 300 m² in hospitals and care homes is divided into two or more fire compartments, each at least half the floor's size, or protected horizontal evacuation areas are provided. In a healthcare building a compartment is at most 1,500 m².

Source: BYKHY 49(1)(b), Annex 4

→ Quote

Describe your compartment line.

Building use, length and height of the line, doors in the line: our technical team will set the class and document set and get back to you.