GGuide · sizes
Fire door sizes
Under the Turkish Fire Regulation (BYKHY), an escape route door in a new building has a clear opening width of at least 80 cm and a height of at least 200 cm; the clear width of a single-leaf exit door cannot exceed 120 cm. In an existing building, an escape route door is at least 70 cm wide and 190 cm high. The largest size that can be made is set by the profile system.
- Minimum in a new building
- 80 × 200 cm
- Minimum in an existing building
- 70 × 190 cm
- Single leaf maximum
- 120 cm clear width
- Dimension type
- Clear width
01 Regulation
Which sizes does the regulation require for a fire door?
New and existing buildings differ: for a new building the regulation states clear width, for an existing building it states width.
| Sizes | New building | Existing building |
|---|---|---|
| Door width | Clear width at least 80 cm | Width at least 70 cm |
| Door height | At least 200 cm | At least 190 cm |
| Basis | BYKHY 47(1), 47(4) | BYKHY 157(1) |
In a new building, the clear width of a single-leaf exit door is between 80 cm and 120 cm; an escape route door has no threshold (BYKHY 47(1), 47(4)).
02 How it is measured
How is clear width measured?
It is measured between the open leaves, not from the door's overall size.
- 01
On a single leaf
The dimension between the door frame or rebate stop and the face of the leaf opened to 90 degrees.
- 02
On a double leaf
The dimension between the leaf faces with both leaves open to 90 degrees.
- 03
Not the door's overall size
Frame and leaf thickness are deducted; overall size, glass size and clear opening are all different.
- 04
By number of occupants
With 50–500 people on a floor, an escape route is at least 100 cm; with 501–2,000 people, at least 150 cm; in a high-rise building, at least 120 cm.
Source: BYKHY 47(4), 33(1), 33(2), 33(5)
03 Maximum size
What is the largest size a glazed fire door is made in?
The profile system sets the limit; the door's report sets the size valid for each rating.
Single leaf
FR90 single leaf
An Aliplast FR90 single-leaf door is made up to 1,650 × 2,870 mm, FR65 up to 1,400 × 2,500 mm. Single leaf
Double leaf
FR90 double leaf
An Aliplast FR90 double-leaf door is made up to 3,170 × 2,870 mm, FR65 up to 2,690 × 2,500 mm. Double leaf
Table
All size limits
Frame depth, glass thickness, rating and partition sizes in one table. Technical file
04 FAQ
About fire door sizes
The door size depends on the number of people on the floor and the door's location. Send us the plan and we will determine the opening size and leaf layout together.
What is the minimum size of a fire door in cm?
In a new building, an escape route door has a clear width of at least 80 cm and a height of at least 200 cm. In an existing building, an escape route door is at least 70 cm wide and at least 190 cm high.
Source: BYKHY 47(1), 157(1)
What is the maximum width of a single-leaf fire door in cm?
The clear width of a single-leaf exit door cannot be less than 80 cm or more than 120 cm. If a wider opening is needed, a double leaf is used.
Source: BYKHY 47(4)
How is clear width measured?
On a single leaf it is measured between the frame or rebate stop and the face of the leaf opened to 90 degrees; on a double leaf, between the leaf faces with both leaves open to 90 degrees.
Source: BYKHY 47(4), 33(5)
Can a fire door have a threshold?
Escape route doors must have no threshold; revolving doors and turnstiles also cannot be used as exit doors.
Source: BYKHY 47(1)
→ Quote