S30Fire criteria · duration

EI30 fire door

An EI30 door maintains its integrity (E) and insulation (I) for 30 minutes in a fire. In hotels and dormitories, 30 minutes is enough for doors opening onto an inner or outer corridor and for the exit door opening onto an external route. Escape stair, smoke barrier and compartment doors, however, need at least 60 minutes.

EI30 fire door Turkey – hotel breakfast room entrance
30-minute door in a hotel corridor
The letters in EI30
E integrity · I insulation
Hotel inner corridor
At least 30 min
External route exit
30 min
Stair door
At least 60 min
Polflam EI30 glass
20 mm

01 Enough?

Is 30 minutes enough for your door?

Choose where the door opens; whether 30 minutes is enough shows on the scale and below.

1Location

30minutesminimum · this location

In hotels and dormitories, a door opening onto the inner corridor resists fire for at least 30 minutes and is self-closing; the wall between room and corridor is 60 minutes. EI30 is enough.

  • EI30 is enoughGlass 20 mm
  • Self-closingWith a closer
  • Wall 60 minThe wall the door sits in
  • Smoke-tightRequired by the article

Source: BYKHY 4(1)(tt), 37(2), 38(3), 47(3), 50(1)(b), 50(2)(b), 50(6)(a)

0306090120minutesrequired by locationEI30 doorEI60 doorEI90 doorMINUTE SCALE · diagram–
Required hereEI30EI60EI90

02 What the door needs

What to look for in a 30-minute door

First the function room door opening onto the hotel corridor, then the external route; the view you choose pauses when you tap it.

EI30 fire door Turkey – hotel meeting room

1 / 2 · Function room door opening onto a hotel corridorCamera in the hotel corridor; fire in the meeting room.

Rating≥ 30 minGlass20 mm

  1. DurationA door opening onto the inner corridor resists fire for at least 30 minutes.
  2. CloserThe door is fitted with a self-closing device.
  3. GlassThe glass of the EI30 door is 20 mm Polflam EI30.

Source: BYKHY 50(1)(b), 50(1)(ç); Polflam catalogue

03 Floor plan

Where is 30 minutes enough on a hotel floor?

An inner corridor with rooms on both sides, a smoke barrier dividing the corridor, a stair, an external route at the end of the corridor and an annex block with a gallery. When you choose a rule, its location turns orange on the plan.

What does EI30 tell you?

In Annex 3/A, E stands for integrity and I for insulation; an EI30 door maintains both for 30 minutes in a fire.

ExampleSecond room door opening onto the corridor on the plan: EI 30.

Source: BYKHY Annex 3/A

internal corridorinternal corridorroomroomstairsmoke stopexternal walkwayexternal corridorHOTEL FLOOR PLAN · diagramEI 30123456
WallSelected rule

04 Four locations

Where is 30 minutes enough, and where is it not?

30 minutes is enough in two places and not in the other two; choose a location and the required duration appears beside it.

05 Your project

Which doors in your project need only 30 minutes?

Where the door opens sets the duration; four questions are enough.

  1. 01

    Which corridor does the door open onto?

    If it is the inner or outer corridor of a hotel or dormitory, 30 minutes is enough.

  2. 02

    Does it open onto an external route?

    30 minutes is specified for an exit door opening onto an external route.

  3. 03

    Does it open onto a stair?

    30 is not enough for a stair door: at least 60, and 90 for a basement or more than 4 storeys.

  4. 04

    Does it cut across a line?

    A door in a smoke barrier or compartment line needs 60 minutes.

Send your door list and we will pick out together the doors where 30 minutes is enough. A floor plan showing the corridors the doors open onto is enough.

Send the list

06 Products

Which glazed doors are made as EI30?

Polflam's 20 mm EI30 glass, with FR65 or FR90 profiles.

  1. FR65

    Interior door

    Single and double leaf in hotel and residence corridors, EI30 or EI60. Aliplast FR65

  2. FR90

    Single leaf

    Indoors and at exits onto an external route; EI30 to EI90. Single leaf

  3. FR90 Slide

    Automatic sliding

    Aliplast's automatic sliding system is in class EI30. Automatic sliding

At stair, smoke barrier and compartment doors the duration rises to 60 minutes. EI60 fire door

Abay Yapı Sistemleri

Trusted for 30 years.

We make EI30 doors with Aliplast FR65 and FR90 profiles and 20 mm Polflam glass, to each project's dimensions in our Istanbul workshop.

154
corporate references
Aliplast
authorised manufacturer and distributor in Turkey
Polflam
partner for fire-resistant glass
Istanbul
head office and production, Istanbul
EI30 fire door project Turkey – double leaf with panic bars, side and top lightsEI30 fire door project Turkey – double leaf held open in a lift lobbyEI30 fire door project Turkey – stair front at a restaurant entrance
Lobby passage door · Double leaf · side and top lights
  1. 01Project and useBuilding type, required rating, door location
  2. 02Size and openingOverall size, clear width, opening direction
  3. 03System and hardwareProfile, glass, lock, closer
  4. 04Quote and productionScope agreed, delivered with the document set

Projects

A selection of the doors we have installed in corridors, lobbies and passages.

Our doors opening onto corridors, lobbies and passages. Tap an image to open it and use the arrows to move on.

07 Document set

Which document states the 30 minutes of an EI30 door?

The door's class is in its own system's classification; the 20 mm of the glass is in the Polflam declaration.

Four checks at handover

  1. Class. The document must read at least EI 30.
  2. System. FR65, FR90 or FR90 Slide: the document must match the door's system.
  3. Closer. A self-closing device is mandatory on doors opening onto a corridor or an external route.
  4. Glass. The door uses the 20 mm EI30 glass tested in the document.
  • ClassificationAliplast FR90 Slide automatic sliding doorEI 30Document centre
  • ClassificationAliplast FR65 door and fixed partitionEI 30 · EI 60Document centre
  • DeclarationPolflam EI30 glass20 mmDocument centre
  • AuthorisationAliplast manufacturing authorisationAbay Yapı's manufacturing authorisationDocument centre

Source: Aliplast and Polflam documents

Request the document set for your 30-minute doors. The set is prepared for the door's system and size.

Document centre

08 FAQ

About EI30 fire doors

In a hotel most doors are 30 minutes, but stair and smoke barrier doors need 60. Send your floor plan and we will mark together which door needs which duration.

0216 428 38 20Send a question

What does EI30 mean?

A door marked EI30 maintains its integrity (E) and insulation (I) for half an hour in a fire. The meanings of E and I are given in the regulation's Annex 3/A table.

Source: BYKHY Annex 3/A

Where are EI30 fire doors used?

In hotels and dormitories, 30 minutes is enough for doors opening onto an inner or outer corridor and for the exit door opening onto an external route. All of these doors are fitted with a self-closing device.

Source: BYKHY 37(2), 50(1)(b), 50(2)(b)

Can EI30 be used for a stair door?

A stair door needs at least 60 minutes; on a stair serving a basement or more than 4 storeys the duration is 90 minutes. This door needs EI60 or EI90.

Source: BYKHY 47(3)

How thick is EI30 fire glass?

Polflam EI30 glass is 20 mm, 5 mm thinner than EI60 glass. The door's 30 minutes are shown by the document in which glass and profile were tested together.

Source: Polflam catalogue

How many minutes should a hotel function room door opening onto the corridor resist?

Function rooms and similar spaces opening onto the bedroom corridor are separated to the same level as the rooms; the door opening onto the corridor resists fire for at least 30 minutes and is self-closing.

Source: BYKHY 50(1)(b), 50(1)(ç)

What is the difference between EI30 and EI60?

There is half an hour between the two classes. Smoke barrier, compartment line and escape stair doors need at least 60 minutes; EI30 is not enough in these places. Polflam glass is 20 mm in EI30 and 25 mm in EI60.

Source: BYKHY 4(1)(tt), 47(3), 50(6)(a); Polflam catalogue

Can an automatic sliding door be EI30?

Yes: the FR90 Slide automatic sliding system is classified EI30. It is made as single or double leaf; maximum size 4.90 × 3.50 m.

Source: Aliplast FR90 Slide classification

→ Quote

Tell us about your EI30 doors.

Write where the doors open and their sizes: our technical team will identify the doors where 30 minutes is enough, the class and the document set, and get back to you.

Call · 0216 428 38 20Email

Production
Istanbul

Quote form* required field

CallRequest a quote