In a shopping centre, the fire door stands on the compartment line that divides the shopping floor and at the entrances to the escape stairs. In a commercial building, a compartment is at most 2,000 m² where there are no fire control systems; the door on the line carries the line's fire rating. The exit door of a shop with more than 50 occupants opens in the escape direction and is not kept locked; revolving doors and turnstiles do not count as exits.

Shopping mall fire door Turkey – glazed partition and double leaf closing off a corridor
Compartment door in a shopping centre corridor
Occupant calculation in shops
5 m² per person
Door of a shop for over 50 people
Opens in the escape direction
Revolving door and turnstile
Not counted as an exit
Compartment area in commercial use
Up to 2,000 m²
Travel distance (without sprinklers)
One direction 15 m · two directions 45 m

01 Exit width

How wide should your shop's exit doors be?

Enter the sales area and choose where the door opens; the plan draws the opening at the calculated width.

2Where does the door open?

150cmtotal exit width · minimum

300 people; at an exit opening outside, 100 people pass per 50 cm unit. Total exit width at least 150 cm; each escape route at least 100 cm.

  • Opens in the escape directionAbove 50 occupants
  • Revolving doors do not countNor do turnstiles
  • Never kept lockedOpens by hand
  • Compartment 2,000 m²Above this, divided or systems added

Source: Turkish Fire Regulation (BYKHY) 32(2), 33(1), 47(1), 47(2), Annex 4, Annex 5/A, Annex 5/B

–sales areaMall corridorSHOP PLAN · diagram, opening to scale0 – 2 m
Exit openingEscape directionWall

02 What the door needs

What should you check on a shopping centre door?

First the compartment door across the corridor, then the revolving door at the main entrance and the exit doors beside it; tap a tab to fix the view.

Shopping mall fire door Turkey – compartment crossing with fixed side and top lights

1 / 2 · Door on the compartment lineThe other half of the shopping centre is on fire; this side is clear.

Area≤ 2,000 m²DirectionTowards escape

  1. DoorThe door on the line is fire-resistant; it carries the line's rating at the junctions too.
  2. DirectionIn a section with more than 50 occupants, the door opens in the escape direction.
  3. Glazed partitionThe sides and top of the door are also part of the line; no non-fire-resisting opening is left on the line.

Source: BYKHY 24(7), 47(2), Annex 4

03 Shopping centre floor

How are the doors arranged on a shopping centre floor?

Shopping centre ground floor: concourse, atrium, shops, large store, main entrance and two escape stairs. When a rule is selected, its location on the plan is drawn in orange.

Compartment in commercial use at most 2,000 m²

In a commercial building, a fire compartment is at most 2,000 m²; if suitable fire control systems such as detection, sprinklers and smoke extraction are installed, the limit is lifted. The door and glazed partition on the line carry the line's rating.

ExampleOn the plan, a line running west of the large store divides the floor in two.

Source: BYKHY Annex 4, 24(7)

atriumgalleryanchor storeSHOPPING MALL GROUND FLOOR PLAN · 1/600K0 – 10 m461235
WallEscape stairEscape route

04 Four locations

Where else are fire doors found in a shopping centre?

Four situations in shopping centres; choose a location and the requirements for the door and partition there are marked alongside.

05 Your project

Which fire doors does your shopping centre need?

These four answers determine the compartment, shop and plant area doors.

  1. 01

    How many m² are the shops?

    5 m² per person is used; the door of a shop over 250 m² opens in the escape direction.

  2. 02

    How large is the floor area?

    In commercial use a compartment is at most 2,000 m²; with suitable fire control systems the limit is lifted.

  3. 03

    How many floors, and how many m² in total?

    Sprinklers are mandatory in multi-storey shops and shopping premises with a total area over 2,000 m².

  4. 04

    Is there a cinema, food court or car park?

    Each is separated under its own rule: cinema exits, kitchen partitions, car park walls.

Let's list the compartment and exit doors of your shopping centre together. Send the floor plans and shop areas, and our technical team will review them.

Send the project

06 Glazed door

Can a shopping centre fire door be glazed?

The compartment door and partition across the concourse, and the service and stair doors, are made with Aliplast profiles and Polflam glass.

  1. Concourse line

    Double leaf

    A glazed door across a wide concourse, opening in the escape direction. Double leaf

  2. Wide concourse

    With side lights

    Where the concourse is wider than the door opening, a door with fixed glazing on both sides. With side lights

  3. Above the door

    Fixed glass partition

    Profiled glazing that closes the top of the door up to the concourse ceiling. Fixed partition

The rating of the line and the opening direction of the door are documented together with the door's size and number of leaves. Aliplast FR65

Abay Yapı Sistemleri

Trusted for 30 years.

We make compartment and exit doors for shopping centres with Aliplast profiles and Polflam glass in our Istanbul workshop, to each project's dimensions.

154
corporate references
Aliplast
authorised manufacturer and distributor in Turkey
Polflam
partner for fire-resistant glass
Istanbul
head office and production, Istanbul
Shopping mall fire door project Turkey – double leaf held open in a lift lobbyShopping mall fire door project Turkey – double leaf with panic bars, side and top lights
Lift lobby · Double leaf · top light
  1. 01Project and useBuilding type, required rating, door location
  2. 02Size and openingOverall size, clear width, opening direction
  3. 03System and hardwareProfile, glass, lock, closer
  4. 04Quote and productionScope agreed, delivered with the document set

Projects

Wide passage doors from our reference projects.

Top row: our double-leaf and side-light doors suited to dividing a concourse; below: single-leaf and service doors. Tap a photo; browse with the arrows.

07 Document set

Which documents are required for shopping centre fire doors?

The door on the line meets the line's rating and the exit door meets the calculated width; at handover both are shown with documents.

Four checks at handover

  1. Rating. The rating in the classification report of the door on the line must not be shorter than the line's rating.
  2. Direction. The door of a crowded section must open in the escape direction and be openable by hand.
  3. Lock. Any security lock must be connected to the emergency control system.
  4. Width. The clear width of the doors must meet the calculated exit width.
  • ClassificationClassification report for the compartment doorWith number of leaves and sizeRequest
  • ClassificationClassification report for the concourse partitionWith height and glass sizeRequest
  • DeclarationDeclaration of performanceCE markedRequest it
  • DrawingLine, ceiling and shopfront junction detailsDWGRequest

Source: Turkish Construction Products Regulation 6(1), 10(2)

Request the document set for the shopping centre doors. The set is prepared for the location, rating and size of each door.

Request the document set

08 FAQ

About shopping mall fire doors

In a shopping centre, the compartment lines and exit widths are finalised in the architectural design and the fire brigade approval. Send the plans; let's mark the direction and class of each door together.

0216 428 38 20Send a question

How many minutes should a shopping centre fire door resist fire?

The door on the compartment line carries the line's rating; a compartment resists fire for at least 60 minutes. The escape stair door resists fire for 60 or 90 minutes and is smoke-tight; kitchen partitions resist fire for at least 120 minutes.

Source: BYKHY 4(1)(tt), 24(7), 47(3), 57(3)

What is the maximum size of a compartment in a shopping centre?

2,000 m² in a commercial building. If suitable fire control systems such as detection, sprinklers and smoke extraction are installed, the compartment area in a commercial building is unlimited.

Source: BYKHY Annex 4

Which way should a shop door open?

The exit door of a shop with more than 50 occupants opens in the escape direction. Since 5 m² per person is used for shops, this means shops over 250 m²; the door opens by hand and is not kept locked.

Source: BYKHY 47(2), Annex 5/A

Is an exit door needed next to the revolving door at a shopping centre entrance?

Revolving doors and turnstiles cannot be used as exit doors; at the main entrance, exit is provided by hinged doors. These doors open outwards, open by hand and are not kept locked.

Source: BYKHY 47(1), 47(2)

How wide should a shop's exit door be?

The number of people is divided by the number of people who can pass through a 50 cm unit and multiplied by 0.5 m. For shops, 5 m² per person is used; 100 people pass per unit at an exit opening outside and 80 at internal doors. No exit may be narrower than 80 cm.

Source: BYKHY 33(1), 32(2), Annex 5/A, Annex 5/B

Are sprinklers mandatory in a shopping centre?

An automatic sprinkler system is mandatory in multi-storey shops and in shopping, commercial and entertainment premises with a total area over 2,000 m².

Source: BYKHY 96(2)(d)

What should an atrium in a shopping centre be like?

The atrium area is in principle not less than 90 m², and natural or mechanical smoke control is provided in the atrium. A void smaller than 90 m² is surrounded on every floor by a smoke curtain at least 45 cm deep.

Source: BYKHY 24(5)

→ Quote

Tell us about your shopping centre's doors.

Number of floors, floor area, compartment lines, shop areas: our technical team will determine the doors, their class and the document set, and get back to you.