P7Products · technical file
Glazed fire door technical file
The technical file contains Aliplast FR65 and FR90 profile sections, the system's size limits, the door's classification report, the declarations of performance (DoP) for Polflam glass and DWG details. Reports are valid for the defined product and field of application; the file is shared on request, within the scope of a project.
- Systems
- Aliplast FR65 · FR90
- Door ratings
- EI30 · EI60 · EI90
- Partition ratings
- EI30 – EI120
- Glass
- Polflam, 20–69 mm
01 What is in the file
Which documents are in the technical file?
Six parts; each is useful at a different stage of the project.
Section
Profile sections
Frame, leaf and fixed partition sections for FR65 and FR90, with glass, seal and fixing details. Request it
Sizes
Size limits
The largest door and partition sizes the system can be made in; summarised in the table below. Go to the table
Report
Classification report
The configuration in which the door was tested, its rating and field of application. The report is valid for the defined product. Document check
Declaration
Glass declaration of performance
The declarations for Polflam EI60 and EI90 glass belong to the glass product; on their own they are not a door classification. Fire-resistant glass
Drawing
DWG details
Door, fixed glass, wall and ceiling junction details are supplied adapted to the project. Request it
Specification
Specification text
Specification wording for tenders and project documents, for EI30, EI60, EI90 and EI120 classes. Request it
02 Size limits
Up to what size are FR65 and FR90 systems made?
Sizes in mm, width × height; the door's overall size, glass size and clear opening are all different.
| Property | FR65 | FR90 |
|---|---|---|
| Frame / leaf | 65 / 65 mm | 90 / 90 mm |
| Door rating | EI30, EI60 | EI30, EI60, EI90 |
| Partition rating | EI30, EI60 | EI30 – EI120 |
| Glass thickness | 17–25 mm | 20–69 mm |
| Single leaf, maximum | 1,400 × 2,500 | 1,650 × 2,870 |
| Double leaf, maximum | 2,690 × 2,500 | 3,170 × 2,870 |
System details: Aliplast FR90 Aliplast FR65
03 FAQ
About the technical file
If you are not sure which part of the file you need, tell us your project's stage and we will choose the right documents together.
Does the glass declaration of performance replace the door's rating document?
No. The declarations of performance for Polflam glass belong to the glass product. The rating of the door or partition is shown by the classification report in which the glass and profile were tested together.
Does the maximum size in the table apply to every rating?
The values in the table show the system's limits; they do not mean automatic approval for every fire rating. For the rating, glass type, leaf layout and hardware, the field of application of the relevant report applies.
Is the door's overall size the same as the clear opening?
No. The door's overall size, glass size and clear opening are all different. On an escape route, the dimension the regulation requires is the clear opening width: on a single leaf, the distance between the frame and the leaf opened to 90 degrees.
Source: BYKHY 33(5)
When and how is the technical file shared?
Choose the system and rating in the form. Sections, reports, declarations of performance and current technical information are shared within the scope of the project.
→ File request
Which file do you need?
System, rating and project stage: we will share the files within the scope of your project.
- Phone
- +90 216 428 38 20
- abay@abayyapi.com
- Production
- Istanbul