Office building fire door

In an office building, the fire door stands first and foremost at the entrance to the escape stair. This door is smoke-tight and self-closing; if it serves fewer than 4 floors it resists fire for at least 60 minutes, and if it serves a basement or more than 4 floors, for at least 90 minutes. An office building has at least two independent escape stairs; in an office tower over 51.50 m, a fire safety lobby is built in front of the stair.

Office building fire door Turkey – office tower lift lobby glass partition
Lift lobby door on an office tower floor
Stair door, fewer than 4 floors
At least 60 minutes
Basement or more than 4 floors
At least 90 minutes
Escape stair
At least two, independent
Lobby door above 51.50 m
At least 90 min, smoke-tight
Compartment area in offices
Up to 8,000 m²

01 Number of floors

How many minutes should the stair door in your office building resist fire?

Enter the number of floors, the basements and the area of one floor; the section shows the rules that change with height. A floor height of 3.50 m is assumed in the calculation.

90minutesstair door · minimum

12 floors and 2 basements, building height ≈ 49 m. At least two independent escape stairs are required. The stair door resists fire for at least 90 minutes.

  • Two escape stairsUnless the single-stair conditions are met
  • One compartment every three floorsFloors above 21.50 m
  • SprinklersOnce the building exceeds 30.50 m
  • Fire safety lobby, firefighting liftOnce the building exceeds 51.50 m

Source: Turkish Fire Regulation (BYKHY) 47(3), 52(1), 24(4), 96(2)(a), 34(7), 63(2), Annex 5/A

21.50 mcompartment30.50 msprinklers51.50 msafety lobby±0.002 basements12 storeys · ≈ 42 m
3-floor compartmentStair doorFire safety lobby

02 What the door needs

What should you check on an office building door?

First the floor door of the escape stair, then, in a high-rise office tower, the door of the fire safety lobby in front of the stair; tap a tab to fix the view.

Office building fire door Turkey – office tower stair landing

1 / 2 · Escape stair doorThe camera is in the stair; the fire is on the office floor.

Door60 / 90 minWidth≥ 80 cm

  1. DoorResists fire for at least 60 or 90 minutes; the article requires it to be smoke-tight.
  2. Door closerThe door is self-closing; the fire brigade can enter from outside when needed.
  3. WidthClear width at least 80 cm, height at least 200 cm; the door has no threshold.

Source: BYKHY 47(1), 47(3)

03 Office floor

What should the stairs and lobbies on an office floor be like?

Office tower floor plan: open-plan office, meeting room, core, two escape stairs and fire safety lobbies in front of them. Tap a rule; its location on the plan turns orange.

At least two independent escape stairs in an office building

An office building has at least two independent escape stairs or other exits. If the building is lower than 21.50 m, fewer than 50 people are on the floor and three further conditions are met, a single stair is enough.

ExampleOn the plan, there is an escape stair at each end of the floor.

Source: BYKHY 52(1)

stairstairmeetingcoreOFFICE FLOOR PLAN · 1/250K0 – 5 m164532
Fire-resisting wallEscape stairEscape route

04 Four locations

Where else are fire doors found in an office building?

Four situations in office buildings; choose a location and the requirements for the door there are marked alongside.

05 Your project

Which fire doors does your office building need?

These four answers determine the stair, lobby and plant room doors.

  1. 01

    How many floors and basements?

    A basement, or more than 4 floors, raises the stair door rating to 90 minutes.

  2. 02

    What is the building height in metres?

    The 21.50, 30.50 and 51.50 m thresholds bring in compartments, sprinklers and the fire safety lobby.

  3. 03

    How many people will work on one floor?

    In offices, 10 m² per person is used; 50 or more people on a floor rules out the single-stair option.

  4. 04

    Is there a car park or plant room?

    The doors of an enclosed car park and of electrical and generator rooms stand in a compartment wall.

Let's count the stair and lobby doors of your office tower together. Send the section and the typical floor plan, and our technical team will review them.

Send the project

06 Glazed door

Can an office building fire door be glazed?

The stair and lobby doors, and the partition separating the lift lobby from the office, are made with Aliplast profiles and Polflam glass; the 90-minute door uses the FR90 system.

  1. Stair and lobby

    Single leaf

    The floor door of the stair and of the fire safety lobby. Single leaf

  2. Lift lobby

    Double leaf

    A wide glazed door separating the lift lobby from the open-plan office. Double leaf

  3. Around the door

    Fixed glass partition

    Profiled glazing that closes the side and top of the door up to the ceiling. Fixed partition

For stair and lobby doors, the article also requires smoke tightness; this requirement is documented together with the door's size and number of leaves. Aliplast FR90

Abay Yapı Sistemleri

Trusted for 30 years.

We make stair and lobby doors for office buildings with Aliplast profiles and Polflam glass in our Istanbul workshop, to each project's dimensions.

154
corporate references
Aliplast
authorised manufacturer and distributor in Turkey
Polflam
partner for fire-resistant glass
Istanbul
head office and production, Istanbul
Office building fire door project Turkey – single leaf and glass partition in an open-plan officeOffice building fire door project Turkey – bronze-framed single leaf at an escape exitOffice building fire door project Turkey – single leaf with side light at a corridor entranceOffice building fire door project Turkey – wood-effect door with side and top lights
Office escape door · Single leaf
  1. 01Project and useBuilding type, required rating, door location
  2. 02Size and openingOverall size, clear width, opening direction
  3. 03System and hardwareProfile, glass, lock, closer
  4. 04Quote and productionScope agreed, delivered with the document set

Projects

Office and office tower doors from our reference projects.

Top row: our single-leaf doors at stair and lobby entrances; below: lift lobby and corridor crossings. Tap a photo; browse with the arrows.

07 Document set

Which documents are required for stair and lobby doors in an office building?

Stair door 60 or 90 minutes, lobby door 90 minutes; at handover, the rating, smoke class and door closer are shown with documents.

Four checks at handover

  1. Rating. The rating in the classification report must meet the rating required for the number of floors the stair serves.
  2. Smoke. The report for the stair and lobby door must include a smoke leakage class.
  3. Door closer. The door must be self-closing and openable by the fire brigade from outside.
  4. Size. Door opening at least 80 × 200 cm; no threshold.
  • ClassificationClassification report for the stair and lobby doorWith rating and smoke classRequest
  • ClassificationClassification report for the lift lobby partitionWith height and glass sizeRequest
  • DeclarationDeclaration of performanceCE markedRequest it
  • DrawingDoor, wall and floor junction detailsDWGRequest

Source: Turkish Construction Products Regulation 6(1), 10(2)

Request the document set for the stair and lobby doors. The set is prepared for the type, rating and size of the door.

Request the document set

08 FAQ

About office building fire doors

In an office tower, the number of stairs and lobbies is finalised in the architectural design and the fire brigade approval. Send your section and typical floor plan; let's list the doors and their classes together.

0216 428 38 20Send a question

How many minutes should a fire door in an office building resist fire?

An escape stair door resists fire for at least 60 minutes if it serves fewer than 4 floors, and for at least 90 minutes if it serves a basement or more than 4 floors. The fire safety lobby door resists fire for at least 90 minutes; a door in a compartment wall carries the wall's rating.

Source: BYKHY 47(3), 34(2), 24(7)

How many escape stairs should an office building have?

Office buildings have at least two independent escape stairs or other exits. A single stair requires all five conditions: building height below 21.50 m and fewer than 50 people on the floor; suitable travel distances; non-combustible construction products; no highly flammable materials.

Source: BYKHY 52(1)

When is a fire safety lobby mandatory in an office tower?

In a building with a height over 51.50 m, there is at least one firefighting lift and a fire safety lobby is built in front of the escape stair. The firefighting lift opens into this lobby; the lobby area is between 6 and 10 m².

Source: BYKHY 63(2), 34(7), 34(4)

When are sprinklers mandatory in an office building?

An automatic sprinkler system is installed in all non-residential buildings with a building height over 30.50 m. Sprinklers are also mandatory in an enclosed car park with an area over 600 m².

Source: BYKHY 96(2)(a), 96(2)(c)

How many people are counted on an office floor?

In escape calculations, 10 m² per person is used for offices. A 1,200 m² office floor therefore counts as 120 people.

Source: BYKHY 32(1), Annex 5/A

How are the floors of a high-rise office building divided?

In an office building taller than 21.50 m, the floors above this height are divided into fire compartments of three floors each. In an office building, a compartment is at most 8,000 m².

Source: BYKHY 24(4), Annex 4

Must the door opening into an enclosed car park be fire-resistant?

Yes. The walls and floors of the car park have the properties of compartment walls, and there may be no non-fire-resisting opening between compartments; the door into the building is also fire-resistant.

Source: BYKHY 24(2), 24(7)