KFire criteria · duration

Fire door resistance ratings

The number in a fire door's class is the number of minutes the door withstood fire under test conditions; the letters state the type of protection: E integrity, EW integrity and radiation limit, EI integrity and insulation. The door's location decides which rating is needed: room door, compartment, stair, lobby or shaft.

Fire resistance rating Turkey – double-leaf glazed door closing off a corridor
Glazed door that holds back a fully developed fire
Ratings
30 · 60 · 90 · 120 minutes
Class type
E · EW · EI
Door
Up to EI90
Partition
Up to EI120

01 Which rating where

Which fire resistance rating is required where?

Four ratings and their typical locations in the regulation; each has its own detailed page.

  1. EI30 · 30 minutes

    Hotel room door

    In a hotel, a room door opening onto an internal corridor is rated for at least 30 minutes and is self-closing (50(1)(b)). EI30 page

  2. EI60 · 60 minutes

    Compartment and stair

    Compartment boundary at least 60 minutes (4(1)(tt)); the door of a stair serving fewer than 4 storeys at least 60 minutes (47(3)). EI60 page

  3. EI90 · 90 minutes

    Lobby and tall stair

    Fire safety lobby door at least 90 minutes (34(2)); the door of a stair serving a basement or more than 4 storeys at least 90 minutes (47(3)). EI90 page

  4. EI120 · 120 minutes

    Lobby wall and shaft

    Fire safety lobby wall at least 120 minutes (34(2)); in a high-rise building, the services shaft wall at least 120 minutes (25(3)). EI120 page

02 E, EW, EI

What do the E, EW and EI classes mean?

The letter states the type of protection, the number the minutes.

ClassWhat it providesNote
EIntegrity: against the passage of flames and hot gasesNo thermal insulation
EWIntegrity and limiting heat radiation: the glass does not break in a fire and no flame or smoke passes; part of the heat reaches the other sideNot a thermal insulation class · we also make EW30, EW60, EW90, EW120
EIIntegrity and insulation: the glass does not break in a fire, and the temperature rise on the unexposed face is limitedEI30, EI60, EI90, EI120

Glass layers and classes: Fire-rated glass

03 Systems

Up to how many minutes do Abay systems resist fire?

Doors and partitions made with Aliplast profiles and Polflam glass.

ProductAliplast FR65Aliplast FR90
DoorEI30, EI60EI30, EI60, EI90
Fixed partitionEI30, EI60EI30, EI60, EI90, EI120
Location of useInteriorInterior and exterior

04 FAQ

About fire resistance ratings

The rating follows from the door's location and the building. Send us the plan and the door's location; we will set the rating and its certification together.

0216 428 38 20Send a question

What does EI60 mean?

EI60 is the class showing that a door or partition kept both its integrity (E) and its insulation (I) for 60 minutes under test conditions. The number states the minutes, the letters the type of protection.

How many minutes must a fire door resist fire?

The rating depends on the door's location: a hotel room door at least 30, a compartment boundary at least 60, a fire safety lobby door at least 90 minutes.

Source: BYKHY 50(1)(b), 4(1)(tt), 34(2)

Is smoke-tightness part of the fire resistance rating?

No, it is assessed separately. For stair and lobby doors the regulation requires smoke-tightness in addition to the fire resistance rating.

Source: BYKHY 47(3)

Where are 120 minutes required?

The fire safety lobby wall and, in a high-rise building, the services shaft wall are rated for at least 120 minutes. Aliplast FR90 fixed glazed partitions are made up to EI120.

Source: BYKHY 34(2), 25(3)

→ Quote

Let us set your door's rating together.

Door location, number of storeys and use: let us set the rating together.

Call · 0216 428 38 20Email

Production
Istanbul

Quote form* required field