S30Fire criteria · duration
30-minute fire door
A 30-minute door maintains its integrity for 30 minutes in a fire; the class is EI30 or EW30, as the project requires. In hotels and dormitories, 30 minutes is enough for doors opening onto an inner or outer corridor and for the exit door opening onto an external route. Escape stair, smoke barrier and compartment doors, however, need at least 60 minutes.
- Class
- EI30 or EW30
- Hotel inner corridor
- At least 30 min
- External route exit
- 30 min
- Stair door
- At least 60 min
- Polflam EI30 glass
- 20 mm
01 Enough?
Is 30 minutes enough for your door?
Choose where the door opens; whether 30 minutes is enough shows on the scale and below.
1Location
30minutesminimum · this location
In hotels and dormitories, a door opening onto the inner corridor resists fire for at least 30 minutes and is self-closing; the wall between room and corridor is 60 minutes. 30 minutes is enough.
- 30 minutes is enoughGlass 20 mm
- Self-closingWith a closer
- Wall 60 minThe wall the door sits in
- Smoke-tightRequired by the article
Source: BYKHY 4(1)(tt), 37(2), 38(3), 47(3), 50(1)(b), 50(2)(b), 50(6)(a)
02 What the door needs
What to look for in a 30-minute door
First the function room door opening onto the hotel corridor, then the external route; the view you choose pauses when you tap it.
1 / 2 · Function room door opening onto a hotel corridorCamera in the hotel corridor; fire in the meeting room.
- DurationA door opening onto the inner corridor resists fire for at least 30 minutes.
- CloserThe door is fitted with a self-closing device.
- GlassThe glass of the 30-minute door is 20 mm Polflam EI30.
Source: BYKHY 50(1)(b), 50(1)(ç); Polflam catalogue
2 / 2 · Exit door opening onto an external routeCamera on the external route; fire inside the building.
- DurationThe exit door opening onto the external route resists fire for 30 minutes.
- CloserThe door is fitted with a self-closing device.
- RouteAn external route may be used as the escape route instead of an inner corridor.
Source: BYKHY 37(1), 37(2)
03 Floor plan
Where is 30 minutes enough on a hotel floor?
An inner corridor with rooms on both sides, a smoke barrier dividing the corridor, a stair, an external route at the end of the corridor and an annex block with a gallery. When you choose a rule, its location turns orange on the plan.
What does EI30 tell you?
In Annex 3/A, E stands for integrity and I for insulation; an EI30 door maintains both for 30 minutes in a fire.
ExampleSecond room door opening onto the corridor on the plan: EI 30.
Source: BYKHY Annex 3/A
Door opening onto a hotel inner corridor: 30 minutes
In hotels and dormitories, doors opening onto the inner corridor resist fire for at least 30 minutes and are self-closing; the wall between room and corridor is 60 minutes.
ExampleAll room doors on both sides of the corridor on the plan: 30.
Source: BYKHY 50(1)(a), 50(1)(b)
Door opening onto an outer corridor: 30 minutes
Rooms are separated from the outer corridor by a 60-minute wall; a door opening onto the outer corridor resists fire for at least 30 minutes and is self-closing.
ExampleFour doors opening onto the gallery in the annex block: 30.
Source: BYKHY 50(2)(a), 50(2)(b)
Exit door opening onto an external route: 30 minutes
An external route may be used as the escape route instead of an inner corridor; the exit door opening onto it resists fire for 30 minutes and is self-closing.
ExampleDoor from the end of the corridor onto the external route: 30.
Source: BYKHY 37(1), 37(2)
30 is not enough at a smoke barrier: 60 minutes
The smoke barrier dividing the corridor and the escape door in it resist fire for at least 60 minutes; the door is smoke-tight.
ExampleSmoke barrier cutting the corridor in the middle on the plan, and its door: 60.
Source: BYKHY 50(6)(a)
30 is not enough at a stair door: 60 or 90
An escape stair door needs at least 60 minutes, and 90 minutes on a stair serving a basement or more than 4 storeys.
ExampleStair door opening onto the corridor on the plan: 60 or 90.
Source: BYKHY 47(3)
04 Four locations
Where is 30 minutes enough, and where is it not?
30 minutes is enough in two places and not in the other two; choose a location and the required duration appears beside it.
Fire side
Escape side
- In a student residence In a dormitory, the door of a study room opening onto the inner corridor resists fire for at least 30 minutes and is self-closing. BYKHY 50(1)(b)30 Hotel page
- On a roadside motel's outer corridor A door opening onto the outer corridor resists fire for at least 30 minutes; the wall separating the rooms from the outer corridor is 60 minutes. BYKHY 50(2)(a), 50(2)(b)30 Hotel page
- On a hotel stair 30 minutes is not enough for a stair door: at least 60, and 90 minutes on a stair serving a basement or more than 4 storeys. BYKHY 47(3)6090 Hotel page
- At a hotel smoke barrier The door of the smoke barrier dividing the corridor needs at least 60 minutes and must not let smoke through; 30 minutes is not enough here. BYKHY 50(6)(a)60 Hotel page
05 Your project
Which doors in your project need only 30 minutes?
Where the door opens sets the duration; four questions are enough.
- 01
Which corridor does the door open onto?
If it is the inner or outer corridor of a hotel or dormitory, 30 minutes is enough.
- 02
Does it open onto an external route?
30 minutes is specified for an exit door opening onto an external route.
- 03
Does it open onto a stair?
30 is not enough for a stair door: at least 60, and 90 for a basement or more than 4 storeys.
- 04
Does it cut across a line?
A door in a smoke barrier or compartment line needs 60 minutes.
Send your door list and we will pick out together the doors where 30 minutes is enough. A floor plan showing the corridors the doors open onto is enough.
Send the list06 Products
Which systems are used for 30-minute glazed doors?
Polflam's 20 mm EI30 glass, with FR65 or FR90 profiles.
FR65
Interior door
Single and double leaf in hotel and residence corridors, 30 or 60 minutes (EI30, EI60). Aliplast FR65
FR90
Single leaf
Indoors and at exits onto an external route; 30 to 90 minutes. Single leaf
FR90 Slide
Automatic sliding
Aliplast's automatic sliding system is rated 30 minutes (EI30). Automatic sliding
At stair, smoke barrier and compartment doors the duration rises to 60 minutes. 60-minute fire door
Abay Yapı Sistemleri
Trusted for 30 years.
We make 30-minute doors with Aliplast FR65 and FR90 profiles and 20 mm Polflam glass, to each project's dimensions in our Istanbul workshop.
- 154
- corporate references
- Aliplast
- authorised manufacturer and distributor in Turkey
- Polflam
- partner for fire-resistant glass
- Istanbul
- head office and production, Istanbul



- 01Project and useBuilding type, required rating, door location
- 02Size and openingOverall size, clear width, opening direction
- 03System and hardwareProfile, glass, lock, closer
- 04Quote and productionScope agreed, delivered with the document set
Projects
A selection of the doors we have installed in corridors, lobbies and passages.
Our doors opening onto corridors, lobbies and passages. Tap an image to open it and use the arrows to move on.
07 Document set
Which document states the duration of a 30-minute door?
The door's class is in its own system's classification; the 20 mm of the glass is in the Polflam declaration.
Four checks at handover
- Class. The document must read at least EI 30 or EW 30.
- System. FR65, FR90 or FR90 Slide: the document must match the door's system.
- Closer. A self-closing device is mandatory on doors opening onto a corridor or an external route.
- Glass. The door uses the 20 mm EI30 glass tested in the document.
- ClassificationAliplast FR90 Slide automatic sliding doorEI 30Document centre
- ClassificationAliplast FR65 door and fixed partitionEI 30 · EI 60Document centre
- DeclarationPolflam EI30 glass20 mmDocument centre
- AuthorisationAliplast manufacturing authorisationAbay Yapı's manufacturing authorisationDocument centre
Source: Aliplast and Polflam documents
Request the document set for your 30-minute doors. The set is prepared for the door's system and size.
Document centre08 FAQ
About 30-minute fire doors
In a hotel most doors are 30 minutes, but stair and smoke barrier doors need 60. Send your floor plan and we will mark together which door needs which duration.
What does EI30 mean?
A door marked EI30 maintains its integrity (E) and insulation (I) for half an hour in a fire. The meanings of E and I are given in the regulation's Annex 3/A table. A door marked EW30 has W instead of I: it limits heat radiation instead of providing insulation.
Source: BYKHY Annex 3/A
Where are 30-minute fire doors used?
In hotels and dormitories, 30 minutes is enough for doors opening onto an inner or outer corridor and for the exit door opening onto an external route. All of these doors are fitted with a self-closing device.
Source: BYKHY 37(2), 50(1)(b), 50(2)(b)
Can a 30-minute door be used for a stair door?
A stair door needs at least 60 minutes; on a stair serving a basement or more than 4 storeys the duration is 90 minutes. This location needs a 60- or 90-minute door.
Source: BYKHY 47(3)
How thick is EI30 fire glass?
Polflam EI30 glass is 20 mm, 5 mm thinner than EI60 glass. The door's 30 minutes are shown by the document in which glass and profile were tested together.
Source: Polflam catalogue
How many minutes should a hotel function room door opening onto the corridor resist?
Function rooms and similar spaces opening onto the bedroom corridor are separated to the same level as the rooms; the door opening onto the corridor resists fire for at least 30 minutes and is self-closing.
Source: BYKHY 50(1)(b), 50(1)(ç)
What is the difference between a 30-minute and a 60-minute door?
There is half an hour between the two. Smoke barrier, compartment line and escape stair doors need at least 60 minutes; 30 minutes is not enough in these locations. Polflam glass is 20 mm for EI30 and 25 mm for EI60.
Source: BYKHY 4(1)(tt), 47(3), 50(6)(a); Polflam catalogue
Can an automatic sliding door be 30 minutes?
Yes: the FR90 Slide automatic sliding system is classified EI30. It is made as single or double leaf; maximum size 4.90 × 3.50 m.
Source: Aliplast FR90 Slide classification
→ Quote
Tell us about your 30-minute doors.
Write where the doors open and their sizes: our technical team will identify the doors where 30 minutes is enough, the class and the document set, and get back to you.
- Phone
- +90 216 428 38 20
- abay@abayyapi.com
- Production
- Istanbul